Omron E2E-X2MB28 2M: Active for New Industrial Designs

E2E-X2MB28 2M Omron product image

2mm sensing distance, 10V to 30V supply limits, M8 threaded body, -40°C to 85°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 2MM PNP M8 NC
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V

Active status supports design-in, but the target gap decides fit

Active status clears the lifecycle hurdle. The aligned Active lifecycle signals make E2E-X2MB28 2M a candidate for new designs, while stated EU RoHS compliance addresses materials without resolving the electrical and mounting details. The listed 2mm sensing distance is a ceiling, not a promise that every metal target will switch at that gap.

A controller rail must stay within the 10V to 30V supply limits; no allowance above 30V is stated. The -40°C to 85°C operating range bounds temperature, too. A hotter mounting location falls outside it.

The unshielded M8 body needs room around the sensing face

A flush-mounted pocket without clearance work is the wrong place for this unshielded M8 threaded body. It suits a machine input built for PNP-NC, 3-wire switching; an input expecting a normally open signal will read the opposite state.

Cable leads make the harness the buying decision

Will cable leads work on this line? E2E-X2MB28 2M comes boxed with cable leads, not a plug-in connector. Set the termination method and cable routing in the build instructions before committing the harness. A sensor change at the machine won't be a connector swap; it will be a wiring job.

The 1kHz ceiling does not close the wiring or mounting work

1kHz is the listed response-frequency ceiling. It can rule out a faster detection requirement, but it does not establish detection timing for a particular target and mounting geometry. The wire assignments, mechanical drawing, and output-current limit are absent here. Get them before fixing the input wiring or machining the bracket; the frequency figure cannot settle either interface.

View the Win-Source product page for E2E-X2MB28 2M.

Key Takeaways for Engineers & Buyers

  • Keep the target gap within the listed 2mm sensing-distance ceiling.
  • Match the controller input to the PNP-NC, 3-wire output.
  • Get the wire assignments before terminating the cable leads.