Omron E2E-X2ME1-M1: Discontinued, for sustaining designs

E2E-X2ME1-M1 Omron product image

2mm sensing distance, 800Hz response ceiling, M8 threaded body; not for new design-in.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR PROX INDUCTIVE 2MM CYLIND
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 800Hz; Voltage - Supply: 10V ~ 40V

Can this discontinued Omron sensor stay on a running line?

Can we keep this sensor on a running line? Yes, for sustaining designs, but not for a new design-in. One lifecycle signal says EOL and two say Discontinued; treat E2E-X2ME1-M1 as discontinued. It ships in bulk. Secure parts for existing production and plan migration. It is EU RoHS compliant.

Unshielded mounting puts the 2mm distance to the test

Flush metal mounting is a poor assumption for an unshielded sensor. The listed 2mm sensing distance is a starting point, but only tests with the actual target and mounting geometry establish repeatable detection.

The 800Hz response-frequency ceiling bounds repeated-target sensing, but it specifies neither switching delay nor guaranteed capture of every passing target, so test the installation where a missed target stops the cycle. The -40°C to 85°C operating-temperature range sets the sensor’s temperature envelope; it does not establish that sensing distance stays unchanged across that range.

The M8 body fits a machine; the NPN output must fit its input

This isn't a board sensor. The M8 threaded stainless-steel cylinder belongs at a machine sensing point; its NPN-NO, 3-wire output needs a compatible controller input. IP67 describes the sensor’s listed ingress protection, not that of an unspecified mating connector. Connector termination can ease replacement in existing equipment, but it cannot fix an input mismatch.

The supply limits leave wiring and mounting questions open

A 10V to 40V supply range bounds the rail choice, not output loading. The listing gives neither an output load-current limit nor a connector pinout; obtain both before wiring the controller. It also omits a mounting drawing and target-dependent sensing-distance data, so don't treat the 2mm figure as installed clearance without them. An M8 mounting hole alone cannot establish connector compatibility.

View the Win-Source product page for E2E-X2ME1-M1.

Key Takeaways for Engineers & Buyers

  • Test target detection at the listed 2mm sensing distance in the intended mount.
  • Match the controller input to the NPN-NO, 3-wire output.
  • Secure bulk-packed parts for existing production and plan migration.