2mm sensing ceiling, 10V ~ 40V supply limits and M8 threaded body; not for new design-in.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 800Hz; Voltage - Supply: 10V ~ 40V |
A 2mm reach cannot rescue a discontinued sensor
The 2mm sensing-distance ceiling constrains target placement; discontinued status rules out new design-in. E2E-X2MF2-M3 has an EOL label in one lifecycle field and Discontinued in the others. The wording conflicts, but the decision does not: keep this part for sustaining work, not a new machine.
Its inductive, PNP-NC, 3-Wire output can fit an existing control scheme built for that signal. EU RoHS compliance does not change the lifecycle decision.
The supply limit is clear; target capture is not
40V is the listed supply ceiling, not a rail target. The 10V lower bound matters if voltage at the sensor falls below it, and neither supply limit establishes the load the PNP-NC output can drive. The listed 800Hz response-frequency figure sets a ceiling for judging event rate, but it does not establish whether a short target passing this sensor will reliably register at machine speed.
The M8 threaded cylinder suits a threaded sensor mount. Its unshielded construction rules out assuming it can be installed flush in surrounding metal, a mounting choice that matters with a 2mm sensing-distance ceiling.
Bulk packing leaves the sustaining line to manage change
Bulk packing won't simplify line-side handling, but connector termination is defined. Reserve inventory for existing production and schedule migration rather than putting this discontinued sensor on a new build.
The M8 body still needs a drawing and pinout
The wiring isn't settled. The connector pinout is still needed: PNP-NC, 3-Wire identifies the output scheme, not which contact goes to the controller input. A mechanical drawing is absent, so the M8 threaded body alone cannot settle mounting depth or connector clearance. The output load-current limit is missing too, leaving the controller input load unchecked.
View the Win-Source product page for E2E-X2MF2-M3.
Key Takeaways for Engineers & Buyers
- Check target placement against the 2mm sensing-distance ceiling.
- Keep the sensor supply within the listed 10V ~ 40V limits.
- Plan migration from this discontinued part for existing production.