2 mm sensing distance, 10V to 40V supply, M8 body and -40°C to 85°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 800Hz; Voltage - Supply: 10V ~ 40V |
Can this discontinued sensor stay on a running line?
Can we keep E2E-X2MF2 on a running line? Yes, as a sustaining part while inventory is secured and migration is planned. It isn't a new design-in choice. One lifecycle signal says EOL; lifecycle status and product status both say Discontinued. The wording differs, not the decision. EU RoHS compliance does not change it.
The 2 mm reach decides the target gap
2 mm is the listed sensing-distance ceiling, not a guaranteed usable gap for every target. Target position and mounting matter: metal near the unshielded face can reduce usable reach, leaving a target that looks close enough on paper vulnerable to missed detections. The 10V to 40V supply range bounds the rail choice, but 40V is an upper ceiling, not a recommended working rail. The 800Hz response frequency sets a ceiling on how quickly the sensor can respond; it does not specify the pulse width a controller will see. The -40°C to 85°C operating-temperature range establishes environmental fit, but does not say how sensing distance changes across that range.
PNP-NC output narrows the machine fit
Even with the target in range, the input must match. The PNP-NC, 3-Wire output needs an input expecting a normally closed sourcing signal, not an NPN input. Cable leads and the threaded M8 body make this a mounted, wired sensor. IP67 addresses ingress, not sensing reach.
The 2 mm reach leaves mounting details unresolved
Mounting clearance is constrained by the 2 mm reach. The mounting drawing and target-material sensing curve are absent, as is the cable-lead wiring diagram. The drawing must settle clearance around the unshielded body; the curve must establish reach for the actual target. Before rewiring a machine, use the wiring diagram to settle the input connection.
View the Win-Source product page for E2E-X2MF2.
Key Takeaways for Engineers & Buyers
- Check the target gap against the 2 mm sensing-distance ceiling.
- Match the PNP-NC, 3-Wire cable leads to the machine input.
- Secure inventory for existing production; plan migration from E2E-X2MF2.