2mm sensing, 25Hz response ceiling, M12 threaded body; AC supply and input compatibility decide fit.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC |
Active status helps, but the SCR-NO output decides the circuit
The SCR-NO, 2-Wire output limits input choices, but E2E-X2Y1-M1 remains a reasonable new design-in where the control circuit accepts it. Its lifecycle signals agree on Active, with no stated conflict. EU RoHS compliance is listed. Active status doesn't settle the electrical match.
25Hz sets a ceiling on target events
25Hz is the listed response-frequency ceiling, not a guarantee that every target passage will be detected. Don't rely on the sensor above that event rate; test machine timing with the intended target geometry.
The 2mm gap makes mounting the real fit question
A target that can't approach within the listed 2mm sensing distance is wrong for this sensor. For a close metal-detection point, the shielded inductive construction fits only if target travel holds the required gap; target-material correction and hysteresis are absent, leaving trip-point tolerance open.
The threaded M12 cylinder establishes the mounting format, while connector termination leaves cable mating to the assembly. The stated operating temperature range is -40°C to 85°C, and IP67 is the ingress rating. Neither establishes clearance to a moving target or the sealing of a selected mating connector.
20 VAC starts the supply range; the load details are missing
20 VAC is the lower limit of the listed supply range, with 264 VAC as its upper limit; a DC-only circuit is not a fit. Missing output-load limits leave the SCR-NO input match unresolved. The pinout and mounting drawing are also absent; get them before releasing the wiring or threaded installation.
Bulk packaging is the line constraint. Set handling and connector-kitting instructions before the part enters existing production.
View the Win-Source product page for E2E-X2Y1-M1.
Key Takeaways for Engineers & Buyers
- Check target travel against the listed 2mm sensing distance.
- Test the event rate against the 25Hz response-frequency ceiling.
- Set bulk-part handling instructions for the connector-equipped M12 body.