2mm sensing, 25Hz response ceiling, threaded M12 body, and 20 VAC ~ 264 VAC supply limits.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC |
The 2mm gap decides whether this sensor belongs
A 2mm sensing distance puts target placement first. E2E-X2Y1-US supports a close inductive check, not detection across an uncertain machine gap. Active lifecycle signals agree, making it a conditional new design-in rather than a sustaining-only choice. EU RoHS compliance is listed. The AC supply and SCR output must suit the receiving circuit before the sensor belongs on the BOM.
A 25Hz ceiling rules out fast event counting
Fast event counting is the wrong job. The listed 25Hz response frequency is a ceiling; faster events can be missed. For slower position checks, the shielded inductive head and threaded M12 body offer a plausible mounting approach, provided the receiving input accepts the output circuit.
The SCR output needs more than an AC voltage match
The weak point is the input circuit detail, not the sensing principle. SCR-NO, 2-Wire identifies the switching arrangement. The listed supply range starts at 20 VAC and has a 264 VAC ceiling. Those limits narrow the circuit choice but don't establish a usable load: no load-current range or off-state leakage specification is listed, so an input that matches the voltage range could still misread an open sensor.
The wiring diagram and dimensioned drawing are absent too. Those items are needed before assigning cable connections or fixing mounting geometry; the threaded body description settles neither decision.
Bulk handling matters for the cable-lead M12 body
-40°C ~ 85°C is the listed operating-temperature range for E2E-X2Y1-US. It bounds the ambient conditions to consider, not performance at a particular installation. IP67 and the nickel-plated brass M12 body support exposed machine mounting, but they won't protect a lead damaged during assembly. Bulk packaging makes line handling the constraint: protect cable leads during staging and installation so handling damage does not become an intermittent sensor fault.
View the Win-Source product page for E2E-X2Y1-US.
Key Takeaways for Engineers & Buyers
- Set the target gap against the listed 2mm sensing distance.
- Match the receiving input to SCR-NO, 2-Wire before assigning connections.
- Protect cable leads during bulk handling on the line.