A 2mm sensing distance and 25Hz response in a threaded M12 body, with a listed 20 VAC to 264 VAC supply range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC |
The 2mm reach needs a real target test
2mm is the listed sensing distance. It isn't a guaranteed mechanical gap. Target material and installation geometry still decide whether that reach works on the machine, so test the intended target in its mounted position rather than treating the listed distance as guaranteed clearance. The 25Hz response frequency limits the switching-speed case: a faster passing target may be missed even when the static gap looks fine.
Active status permits a new build
New design-in is reasonable. Omron E2E-X2Y1 is Active across the lifecycle fields, with no conflict, and EU RoHS compliance is stated. Neither settles the electrical interface.
The SCR-NO output needs an AC load path
The AC supply range sets the cabinet boundary: 20 VAC is the listed lower limit and 264 VAC the upper ceiling. Do not assume compatibility with a DC-only scheme. E2E-X2Y1 has an SCR-NO, 2-Wire output, which needs a suitable load path rather than wiring for an independent transistor output. The LED gives local indication but cannot establish whether the receiving input reads the switch correctly.
An M12 body fits the machine; cable leads shape assembly
Cable leads add assembly work, but the shielded, threaded M12 cylinder gives this inductive sensor a defined machine-mounting format. The nickel-plated brass body and IP67 ingress rating support an exposed sensor location if the installation preserves that protection; the sensor’s rating doesn't extend to the field connection. The -40°C to 85°C operating-temperature range bounds the sensor environment, not an unqualified cable termination.
Bulk packaging makes lead preparation a line constraint. Put cable routing and lead preparation in the assembly instructions before releasing a running line. The build cannot assume a connectorized termination: this part arrives with cable leads.
The drawing and load limits still decide release
And that mounting call remains conditional: no installation drawing is listed to settle physical clearances, and no cable-lead wiring diagram identifies the conductors. The load-current limit and off-state leakage are also absent. Obtain those limits before specifying the receiving input for the SCR-NO, 2-Wire output.
View the Win-Source product page for E2E-X2Y1.
Key Takeaways for Engineers & Buyers
- Check the 2mm sensing distance against the target and mounting gap.
- Match the 20 VAC to 264 VAC supply range to the machine rail; do not assume DC operation.
- Define cable-lead preparation for bulk-packaged units before line release.