30mm sensing distance, M18 thread, 10V to 30V supply and -25°C to 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 30MM PNP M18 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
The 30mm sensing distance needs an installed-target check
30mm is the listed sensing distance, not a promise of detection at that gap for every target. Omron E2E-X30MB1DL18 5M is Active across its lifecycle fields, making new design-in reasonable; it is also listed as EU RoHS compliant. With an unshielded M18 threaded body, placement near surrounding metal belongs in the bracket decision, alongside the installed-target check that the listed sensing distance alone cannot settle.
The PNP-NO, 3-wire output needs a matching controller input. The 10V to 30V supply range calls for a rail check; 30V is the upper listed limit, not a setpoint to exceed. The -25°C to 70°C operating range calls for an ambient check; 70°C is the upper bound, not extra headroom in a hot enclosure.
IP69K helps, but the installed cable still matters
IP67 and IP69K don't establish cable-exit performance in the installed assembly, but they make the sensor worth considering for a washdown location. The listed 200Hz response frequency is a first screen for event rate, not a minimum detectable target-on time.
Will cable leads fit the running line?
Can the station accept cable leads? Termination is cable leads, and the package is Box; this isn't a connectorized sensor ready to mate with an existing plug. Put the terminated configuration in the harness drawing before build release, because changing a connectorized station to cable leads adds wiring work on the line. Active lifecycle fields agree, with no stated conflict for sustaining use.
The target and wiring details still need drawings
And the installed detection gap remains unresolved: target-material sensing conditions and a mounting drawing are absent, so the listed distance alone cannot set bracket clearance. The output-current limit and wiring diagram are absent too, leaving the controller load and lead assignments open.
View the Win-Source product page for E2E-X30MB1DL18 5M.
Key Takeaways for Engineers & Buyers
- Check the intended target against the listed 30mm sensing distance.
- Match the controller input to the PNP-NO, 3-wire output.
- Specify cable-lead termination in the M18 installation drawing.