Omron E2E-X30MB1TL30-M1: Active for new sensor designs

E2E-X30MB1TL30-M1 Omron product image

30mm inductive sensing, M30 threaded body, 10V–30V supply limits, and −40°C to 85°C operation.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 30MM PNP M30 NO
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V

Can this Active M30 sensor go on a new BOM?

Can this sensor go on a new BOM? The lifecycle fields for E2E-X30MB1TL30-M1 all say Active, with no conflict, and EU RoHS compliance is listed. It's a candidate for new designs and existing production, but electrical and mounting checks still determine whether it fits the machine.

The connector termination is the buying constraint. Settle the mating interface before releasing the BOM for the build; “Box” describes the package, not the connection.

The unshielded M30 body narrows the mounting choice

An input that expects a sinking output is wrong for this sensor. Its PNP-NO, 3-wire switching must match the controller input and intended switching behavior before the 30mm sensing distance matters.

The threaded M30 body is unshielded, so a position chosen for a shielded sensor won't do. Its nickel-plated brass body and listed IP67 and IP69K ingress protection merit consideration where the enclosure faces exposure, but those ratings do not settle mounting clearance.

30mm detection does not settle the trip position

30mm is the listed sensing distance. For E2E-X30MB1TL30-M1, that figure is a starting point for positioning a metal target, not an established switching point for every target material or mounting arrangement. A machine that depends on a precise trip position can miss a target if that distinction is ignored.

The 10V–30V supply listing sets boundaries: 30V is the ceiling, not a setpoint, and 10V is the lower listed boundary. Screen the supply rail against that range, then check the input circuit separately; the supply span does not establish how much load the PNP output can drive.

100Hz sets a separate motion question

100Hz is the listed response frequency. Compare it with the detection sequence, but do not treat it as proof that every passing target will produce a usable signal at the machine’s intended speed; target shape and timing still determine whether the event is captured.

The listed operating-temperature range is −40°C to 85°C. An installation outside those endpoints is ruled out by the listing; one inside them still needs the mounting and electrical checks above.

The M30 connection and trip geometry remain open

Missing application detail is the weak point, not Active status. Wiring needs the pinout and mating connector details from the datasheet; the mount and trip position need a dimensional drawing and target-material sensing curves.

View the Win-Source product page for E2E-X30MB1TL30-M1.

Key Takeaways for Engineers & Buyers

  • Check the target against the listed 30mm sensing distance before fixing the trip position.
  • Keep the supply within the listed 10V–30V boundaries.
  • Resolve the connector interface before releasing the BOM for the build.