30mm sensing distance, 200Hz response frequency, M18 body, and 10V ~ 30V supply range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 30MM PNP M18 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
Active status leaves output logic as the design-in gate
Design it in. Omron's E2E-X30MB2L18 2M is Active across the stated lifecycle fields, and there's no lifecycle reason here to restrict it to sustaining designs. EU RoHS is marked compliant. The harder commitment is its PNP-NC, 3-wire output: an input wired for normally open behavior will see the wrong signal, and correcting that after panels are built can stop a line.
The M18 threaded, nickel-plated brass body and cable leads call for a threaded sensor position with wired termination, not a connectorized socket. Set the input logic and mounting arrangement before releasing a new build. Active status cannot fix either mismatch.
30mm reach does not settle a moving-target check
30mm is the listed sensing-distance limit, not a guaranteed installed gap for every target material. It gives target placement a starting point, but detection still needs a check. The listed 200Hz response frequency limits the event-rate claim; it does not supply a switching waveform or prove that a brief target pass will register. Test the intended target at the intended gap and speed.
The 30V supply limit does not settle enclosure temperature
And the electrical fit has another boundary. The listed supply range is 10V ~ 30V, with 30V as its upper limit; a rail beyond it is outside the stated range. The operating-temperature range of -25°C ~ 70°C puts 70°C at the upper operating boundary, not a target for enclosure ambient. IP67 and IP69K describe the sensor's ingress protection, not protection for the installed cable termination.
Unshielded M18 is a poor flush-mount bet
A fixture that forces a flush metal mount is the wrong fit without clearance evidence. This unshielded M18 body needs surrounding metal accounted for; the 30mm sensing distance alone cannot establish target position in that fixture.
Will the cable-lead order match the build?
Will the cable leads match the build instruction? E2E-X30MB2L18 2M is listed with cable leads and box packaging; keep that termination style on the purchase description for a running line. The wiring diagram and output load-current limit are absent, leaving the PLC input check open. Target correction factors and unshielded mounting clearances are absent too, leaving the installed sensing gap unresolved.
View the Win-Source product page for E2E-X30MB2L18 2M.
Key Takeaways for Engineers & Buyers
- Test the actual target against the listed 30mm sensing distance.
- Match the PLC input to the PNP-NC, 3-wire output.
- Keep the supply within the listed 10V ~ 30V bounds.