30mm sensing distance, 200Hz response, M18 body, and 10V to 30V supply limits.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 30MM PNP M18 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
Active status supports a new machine build
It's active for new designs. Omron lists E2E-X30MB2L18 5M as Active across its lifecycle signals, with no conflicting status. IP67 and IP69K ingress ratings make wet or washdown locations worth evaluating, but cable exit still needs attention. It is EU RoHS compliant.
The 200Hz response sets a timing check
Fast indexing mechanisms are the wrong place to assume this sensor will catch every target: its listed 200Hz response frequency is a limit, not proof of detection at the machine’s actual target speed. The 30mm sensing distance gives a placement target, not a promise across metal targets or mounting geometries. The 10V to 30V supply limits bound rail selection, but don't establish transient tolerance. The -25°C to 70°C operating-temperature range must cover the sensor’s location.
Cable leads make the exact build matter
Will the cable leads fit the line? E2E-X30MB2L18 5M uses cable leads, so match the termination to the installed wiring method rather than assuming a plug-in hookup. Its PNP-NC, 3-wire output must match the controller input and intended normal state; a mismatch can make a correctly sensed target produce the wrong machine response.
The threaded M18 body is nickel-plated brass. Unshielded construction makes nearby metal relevant to placement, so check the cable route inside the machine as well as the mounting position. Put the exact output type and termination on the bill of materials before releasing the assembly.
Unshielded mounting still needs clearance data
Clearance data is missing for the unshielded body, though the M18 threaded form is specified. Target-material correction factors, hysteresis, and a wiring diagram are also absent, leaving detection position and controller hookup unresolved.
View the Win-Source product page for E2E-X30MB2L18 5M.
Key Takeaways for Engineers & Buyers
- Check 200Hz response against target passage timing.
- Test the 30mm sensing distance with the intended target and mounting geometry.
- Specify PNP-NC, 3-wire cable leads on the bill of materials.