30mm sensing distance, 10V ~ 30V supply, M18 body and cable-lead NPN-NC output.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 30MM NPN M18 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
NPN-NC logic decides the design-in
A PNP input or normally open logic rules this sensor out. Omron E2E-X30MC2L18 5M suits an NPN-NC, 3-Wire industrial proximity input; all lifecycle signals say Active, and EU RoHS is listed compliant. With the wrong input logic, the controller sees the wrong detection state.
The supply and temperature bounds leave no room for assumptions
The limits are firm. The listed supply range starts at 10V and has a 30V ceiling; a matching control rail fits, but a transient above that ceiling does not. Operating temperature runs from -25°C to 70°C, so an enclosure rated for washdown does not make a mounting location outside that span acceptable. The listed 200Hz response frequency describes switching rate, not the delay for a particular moving target.
A 30mm claim still depends on the M18 mount
30mm is the listed sensing distance, not a promise that every metal target trips at that spacing. An unshielded M18 threaded body needs mounting space that a flush sensor position may not offer. Moving the mounting face to fit the hardware can also put the target outside the intended detection zone.
The nickel-plated brass body and IP67, IP69K ingress ratings make a wet industrial machine location plausible, but they don’t establish how the installed cable exit will hold up. On a conveyor or fixture with a defined metal target, settle the target spacing before committing the bracket. A mechanically tidy installation can still miss parts without any wiring fault.
Can the running line use the same harness?
Will the running line accept cable leads? If it is wired for a connector, termination work is needed even when the M18 body fits the bracket. The listed box package says nothing about an installed connector. Put the cable-lead termination on the controlled BOM alongside Omron E2E-X30MC2L18 5M before releasing another build.
The bracket and wiring still need drawings
That still leaves the installation details. Target-dependent sensing curves and unshielded mounting clearances are absent from this listing, as are a cable-lead wiring diagram and a mechanical drawing. Get those details before freezing the bracket or input wiring.
View the Win-Source product page for E2E-X30MC2L18 5M.
Key Takeaways for Engineers & Buyers
- Set the controller input for NPN-NC, 3-Wire logic.
- Check the 30mm target gap in the unshielded M18 mount.
- Match the cable-lead termination to the running line’s harness.