Omron E2E-X30MC2L18-R 2M: Active for New Designs

E2E-X30MC2L18-R 2M Omron product image

30mm sensing, 10V to 30V supply limits and M18 threaded mounting with an NPN-NC output.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR INDUCT 30MM NPN M18 NC
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V

Is this M18 sensor a new-design choice?

Can this sensor go on a new machine BOM? E2E-X30MC2L18-R 2M is listed Active, with no lifecycle conflict, and is EU RoHS compliant. Fit is the condition: this unshielded inductive sensor has an M18 threaded body, cable leads and an NPN-NC, 3-wire output, so it won't suit a machine built around a different input state or connection arrangement. Resolve the input and bracket before the part becomes an assembly instruction.

What does the 30mm sensing distance decide?

30mm is the listed sensing distance. It makes E2E-X30MC2L18-R 2M worth checking for a recessed target, but does not establish switching at that gap for every target material or mounting arrangement. Don't fix the sensor position until the actual target has been tested. The 10V to 30V supply limits define the listed electrical range, not compatibility with the machine controller input; the distance figure also leaves clearance around the unshielded body unresolved.

What is missing before the M18 bracket is released?

The M18 mounting drawing and cable-lead wiring diagram are missing, leaving the bracket and input connection open. The threaded body and NPN-NC output still establish the basic mechanical and electrical approach. The target-material sensing curve is missing too.

Can the cable and switching rate work on the line?

Cable routing and the 200Hz ceiling set the line constraints. The M18 thread and cable leads call for a workable cable path on the assembly drawing before this version goes on the BOM; unlike a connectorized sensor, the cable exit is part of the installation, not a detail to settle later.

The 200Hz response-frequency rating is a ceiling, not a guaranteed switching rate for every passing target. A faster event stream can be missed if the machine timing assumes otherwise. The listed operating-temperature range of -25°C to 70°C bounds the intended environment; it does not establish behavior outside that range at this mounting position. IP67 and IP69K are listed for the sensor, but they do not settle protection of the lead termination elsewhere in the machine.

View the Win-Source product page for E2E-X30MC2L18-R 2M.

Key Takeaways for Engineers & Buyers

  • Check the actual target against the listed 30mm sensing distance.
  • Match the machine input to the NPN-NC, 3-wire output.
  • Reserve an accessible route for the M18 sensor’s cable leads.