30mm sensing distance, M18 threaded body, 10V ~ 30V supply, and 200Hz response frequency.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 30MM NPN M18 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
The 30mm reach needs an unshielded M18 layout
30mm is the listed sensing distance. It puts this active inductive sensor in contention where the target passes within reach of a threaded M18 body, but it doesn't establish detection on the actual metal target in the intended mounting. The sensor is unshielded; a layout that assumes a shielded, flush-mounted device starts from the wrong geometry.
Fix the target path before fixing the bracket. A missed detection there is a machine fault, and the 30mm figure alone cannot rule it out.
Will the cable-lead version stay on the running line?
Can we keep this exact cable-lead variant on the running line? E2E-X30MC2L18-R 5M has aligned Active lifecycle signals with no stated conflict, so its lifecycle gives neither a new design nor existing production a reason to reject it. Put the full part number on the BOM: the cable-lead termination matters, and another M18 sensor is not necessarily the same wired assembly. Box describes the packaging, not a connector option. The part is listed as EU RoHS compliant.
The 10V ~ 30V supply bounds determine whether the control rail fits; 30V is the upper limit, not a preferred setpoint. The listed 200Hz response frequency is a ceiling for event-rate planning, not a specification for the pulse timing an input will see. Operating temperature is listed from -25°C to 70°C. Check temperature at the sensor’s mounting point: 70°C is the upper boundary, not permission to ignore heat there.
The wiring and target data still matter
The gaps are specific. The listing has no cable wiring diagram or output load-current limit, leaving the input connection and its load unchecked. Target-material sensing data is also absent, so the 30mm figure cannot settle detection on its own.
NPN-NC rules out a PNP-only input
A PNP-only input is wrong for this 3-wire NPN-NC output; so is an input expecting normally open behavior. The cable leads and threaded M18 body fit a control panel built for normally closed sinking signals, provided the mounting geometry passes the target check.
IP67 and IP69K are listed ingress ratings relevant to a wet industrial location. They do not establish how the cable exit is protected in the finished installation.
View the Win-Source product page for E2E-X30MC2L18-R 5M.
Key Takeaways for Engineers & Buyers
- Check the 30mm sensing distance against the actual target and unshielded mounting.
- Keep the control supply within the listed 10V ~ 30V bounds.
- Match the 3-wire NPN-NC cable leads to an input expecting normally closed sinking behavior.