30mm sensing distance, 10V–30V supply bounds, threaded M30 body and cable leads.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 30MM NPN M30 NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
Active status supports a new inductive-sensor design-in
Design it in. Omron E2E-X30MC2L30 2M is Active, rather than a sustaining-only choice. EU RoHS is recorded as compliant, though no revision or exemption detail is specified. Its NPN-NC cable leads still have to suit the machine input; lifecycle status can't settle that.
Cable leads, not the box, set the purchasing detail
Box packaging says little about installation; cable-lead termination is the stronger constraint for a threaded M30 sensor. Put that termination on the BOM line so the purchased part matches the wiring plan. The built-in LED may help during commissioning, but it does not change how the sensor connects.
Supply bounds do not settle NPN-NC input behavior
10V to 30V mark the listed supply bounds, not an endorsed setpoint: a rail outside them rules out the sensor, while a rail inside them does not establish input compatibility. Its NPN-NC, 3-wire output calls for an input scheme that handles the normally closed state. The listed 100Hz response frequency screens target-passage speed, but without its test conditions it does not promise that every passing target will register.
The 30mm claim depends on where the M30 head sits
30mm is the listed sensing distance, but neighboring metal matters to an unshielded inductive head. The threaded M30 cylinder needs a bracket layout that leaves the sensing face usable; crowd that face and the distance figure alone cannot settle detection at the target.
IP67 and IP69K are listed ingress protections for the sensor, not proof that every installed cable route will tolerate the same exposure. The -40°C to 85°C operating-temperature range defines the stated envelope; the mounting location still has to remain inside it. The nickel-plated brass body and built-in LED don't establish detection with a particular bracket or target.
Output load and unshielded mounting remain open
Output-load uncertainty starts with a missing output-current limit: without it, the load cannot be checked. The wiring diagram, unshielded mounting drawing and sensing-distance conditions for the intended target are also missing, leaving the cabinet connection and bracket unresolved.
View the Win-Source product page for E2E-X30MC2L30 2M.
Key Takeaways for Engineers & Buyers
- Check the machine rail against the 10V–30V supply bounds.
- Check bracket clearance before relying on the 30mm sensing distance.
- Specify cable-lead termination for E2E-X30MC2L30 2M on the BOM.