10V–30V supply bounds, 30mm sensing distance and an unshielded M30 body with NPN-NC output.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 30MM NPN M30 NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
Supply bounds set the first gate for this Omron sensor
The 10V to 30V supply bounds narrow the controller choice for E2E-X30MC2L30-R 2M. The 30V figure is a ceiling, not a chosen rail, and the range says nothing about how much load the output can drive. Get that interface wrong and an otherwise suitable sensor will not work with the input card.
Every listed lifecycle signal says Active, with no status conflict, so this is a reasonable new design-in candidate where the supply, output logic and mechanical installation match. EU RoHS compliance is listed. Neither fact settles the electrical interface.
An unshielded M30 body is wrong for a flush-mount assumption
A flush-mounted pickup is the wrong job for this unshielded M30 cylinder. The listed 30mm sensing distance is a target-position check, not a guarantee for every metal target. IP67 and IP69K support an exposed industrial installation but cannot correct a mount that changes detection.
Will the running line accept cable leads and NPN-NC logic?
Will the existing machine take cable leads? E2E-X30MC2L30-R 2M has cable-lead termination and a threaded M30 body; match the installed cable entry and mount before committing it to a running line. Box packaging is the listed ordering format. It doesn’t turn this into a connectorized sensor, and a harness built for a connector will need a wiring change.
The NPN-NC, 3-wire output must match the controller’s expected idle state. A logic mismatch can look like a permanently detected target rather than a failed sensor. The LED helps with checks at the machine. The listed -40°C to 85°C operating range sets the ambient-temperature boundary for the installation. None of those features makes an incompatible input card usable.
100Hz does not close the switching check
100Hz is the listed response frequency, not a switching-time waveform. That matters if target passage timing is tight. The listing also lacks an output load limit, a cable wiring diagram and a dimensional drawing. Those items are needed to settle the input load, lead assignments and M30 mounting clearance before release.
View the Win-Source product page for E2E-X30MC2L30-R 2M.
Key Takeaways for Engineers & Buyers
- Check the controller supply against the 10V and 30V bounds.
- Test the 30mm target position with the unshielded M30 mounting arrangement.
- Match the NPN-NC, 3-wire output to the controller’s expected idle state.