Omron E2E-X30MC2L30-R 5M: Active for new designs

E2E-X30MC2L30-R 5M Omron product image

30mm sensing distance, 10V to 30V supply, M30 threaded body and NPN-NC output.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 30MM NPN M30 NC
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V

Active status leaves this M30 sensor open to new designs

Active status is clear. E2E-X30MC2L30-R 5M has aligned Active lifecycle signals and stated EU RoHS compliance. New design-in is reasonable where its NPN-NC cable-lead interface fits the machine.

The 30mm reach does not settle the sensing setup

A controller expecting a sourcing output rules this out, as does counting that requires a response frequency above the listed 100Hz ceiling. An inductive sensing setup that accepts an NPN-NC, 3-wire signal is the fit. The listed 30mm sensing distance warrants consideration for a target at that range, but it does not establish the trip point for every target material or mounting arrangement.

The 10V to 30V supply operating range rules out rails outside those limits, while the -40°C to 85°C operating temperature range can screen the machine environment without settling the temperature at the installed sensor. The unshielded M30 threaded body makes bracket placement part of the sensing decision.

Will cable leads fit the assembly process?

Will cable leads fit the line’s termination process? E2E-X30MC2L30-R 5M is listed with cable leads and a Box package. Box describes the packaging, not a connector on the sensor. If the termination isn’t specified in the build instructions before BOM release, an electrically suitable sensor can reach assembly without a defined connection.

The NPN-NC output still needs a load limit

The output-load current rating is missing. NPN-NC alone cannot establish whether E2E-X30MC2L30-R 5M can drive the intended controller input, although the listed 30mm sensing distance and 100Hz response-frequency ceiling narrow the selection. Target-material correction factors and mounting clearances are also absent, leaving the installed detection point unresolved. The missing wiring diagram must settle the cable-lead connections before the input circuit is released.

View the Win-Source product page for E2E-X30MC2L30-R 5M.

Key Takeaways for Engineers & Buyers

  • Match the 10V to 30V supply range to the machine rail.
  • Check the 100Hz response-frequency ceiling against the required count rate.
  • Get the mounting clearances before fixing the M30 bracket.