30mm sensing, 100Hz response, M30 threaded body; 12V ~ 24V supply and -25°C ~ 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 30MM CYL |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NC, 2-Wire; Response Frequency: 100Hz; Voltage - Supply: 12V ~ 24V |
Active status doesn't clear the RoHS conflict
And the release decision remains. E2E-X30MD2L-T 2M is listed Active, supporting new design-in on lifecycle grounds. But its compliance field says RoHS Compliant while its specification list says RoHS Non-Compliant. Hold EU RoHS approval until that conflict is resolved.
The 30mm sensing limit depends on the installation
30mm is the listed sensing-distance ceiling, not a promise of detection at that gap with every target. The unshielded inductive sensor needs a metal target and room around the sensing face of its M30 threaded cylinder. A tighter recess or a required detection gap beyond 30mm leaves the fit unresolved. The listed ambient bounds are -25°C ~ 70°C; a location outside them rules it out.
A 100Hz response ceiling is not a timing guarantee
100Hz is the listed response-frequency ceiling. It rules out faster target events but does not establish switching timing for a tight position window. The 12V ~ 24V supply limits frame the rail check without establishing behavior during a voltage dip. The NC, 2-Wire output must also suit the receiving input: a correctly mounted sensor can still produce the wrong machine state if that interface is mismatched.
Bulk packing puts the M30 body in the handling plan
Bulk packing makes protection of the M30 threads and connector an assembly constraint. Set a kitting method before assembly rather than handling the sensor like a loose fastener. Active status supports continued purchasing; it does not remove that handling step.
Will the connector and target work in the actual machine?
Will the connector mate with the existing harness? Connector termination is listed, but the pinout is not, so the listing cannot settle either the mating question or whether the wiring suits the NC, 2-Wire output. The M30 threaded cylinder also lacks a mounting drawing needed to check the installed envelope and sensing-face position.
The target raises a separate question. The 30mm sensing limit does not establish the achievable gap for the actual target material, and no sensing-distance correction curve is listed. Output leakage current is missing too, leaving the receiving input's off-state behavior unresolved. Close those gaps before committing E2E-X30MD2L-T 2M to a machine build.
View the Win-Source product page for E2E-X30MD2L-T 2M.
Key Takeaways for Engineers & Buyers
- Check the 30mm sensing limit against the actual target and mounting geometry.
- Match the NC, 2-Wire output to the input circuit.