Omron E2E-X3B1D8 2M: Active for New Industrial Designs

E2E-X3B1D8 2M Omron product image

3mm sensing distance, 10V to 30V supply, threaded M8 body, and -25°C to 70°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 3MM PNP M8 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V

Active status leaves this M8 sensor open to new designs

And that leaves E2E-X3B1D8 2M open to new designs: its lifecycle signals agree on Active status, and it is listed as EU RoHS compliant. It comes boxed with cable leads, so assembly instructions need lead termination rather than an assumed connector.

The 3mm reach sets the first placement decision

3mm is the listed sensing distance, not a guarantee that every target will switch at that gap. If the target cannot be brought within range, the output type won't rescue the installation.

The 10V to 30V limits bound the supply rail, with 30V a ceiling rather than a working setpoint; the 1kHz response-frequency limit screens event rate but does not establish switching delay under the intended load.

Cable leads complicate an otherwise compact M8 installation

Cable leads complicate replacement compared with a connectorized installation, even though the shielded, threaded M8 body gives this inductive sensor a defined mounting format. Its PNP-NO, 3-wire output calls for a matching controller input; it isn't interchangeable with a different input scheme.

The -25°C to 70°C operating range bounds ambient selection. IP67 and IP69K describe the sensor's listed ingress protection, not how the cable termination will fare once installed.

The PNP load and M8 mounting details remain open

The wiring is not settled. Without an output-current limit, the match between the PNP-NO output and its controller load remains open. A cable-lead wiring diagram is also absent, leaving lead assignments unresolved. The missing M8 installation drawing likewise leaves bracket dimensions open; neither can be released from these specifications alone.

Target-dependent sensing curves are needed to judge the listed 3mm reach for the intended target. The 1kHz response-frequency limit does not establish switching delay under the intended load. Obtain those details before setting the lead termination and mounting instructions.

View the Win-Source product page for E2E-X3B1D8 2M.

Key Takeaways for Engineers & Buyers

  • Check target spacing against the listed 3mm sensing distance; obtain target-dependent sensing curves.
  • Match the PNP-NO, 3-wire output to the controller input; obtain the output-current limit.
  • Plan cable-lead termination and mounting for the threaded M8 body before releasing the assembly instructions.