Omron E2E-X3B1D8 5M: Active for New Sensor Designs

E2E-X3B1D8 5M Omron product image

3mm sensing ceiling and an M8 threaded body with PNP-NO cable output.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 3MM PNP M8 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V

The 3mm reach sets a close-range detection task

3mm is the sensing-distance ceiling. It does not promise that every target will switch at that clearance; the target and mounting arrangement determine whether the required trip point is attainable. A supply rail outside the 10V ~ 30V bounds is ruled out. The 1kHz response-frequency rating sets a speed limit to assess, but it does not establish detection of every passing target.

Active status supports a new M8 sensor position

New design-in is reasonable. Omron E2E-X3B1D8 5M has matching Active lifecycle and product status, with no listed conflict to hold up a new industrial sensor position. EU RoHS is listed as compliant. On an existing production line, retain the specified PNP-NO, 3-wire interface on the BOM; a different output convention changes what the controller sees when the sensor switches.

Cable leads and the threaded body decide installation fit

That leaves the physical installation. The M8 threaded, shielded, nickel-plated brass body belongs at a machine-mounted detection point; it doesn't belong in a PCB footprint. Cable leads make harness routing part of the installation, so settle the cable path before fixing the bracket rather than planning around a connector that is not specified here.

IP67 and IP69K are listed ingress ratings, but neither settles how the installed cable exit will handle the machine's exposure once the bracket and cable path are fixed. The -25°C ~ 70°C operating-temperature range sets the ambient boundary for the chosen location; positions outside it are not covered. Buy for the cable-lead termination and M8 mount together: either mismatch can stall installation even when the electrical interface is right.

The 3mm limit still needs mounting detail

Mounting geometry governs the 3mm limit. A mounting drawing and wiring diagram are absent; obtain both before releasing the bracket and cable termination. Output load-current limits and response-frequency test conditions are also absent, so the 1kHz rating cannot close the controller-input timing check.

View the Win-Source product page for E2E-X3B1D8 5M.

Key Takeaways for Engineers & Buyers

  • Check the actual target against the listed 3mm sensing-distance ceiling.
  • Match the controller input to the PNP-NO, 3-wire output and 10V ~ 30V supply bounds.
  • Reserve an M8 threaded mounting position and a route for the cable leads.