Omron E2E-X3B1D8-R 5M: Active for New Machine Builds

E2E-X3B1D8-R 5M Omron product image

3mm sensing distance, 10V–30V supply limits, M8 body and -25°C to 70°C operating temperature.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 3MM PNP M8 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V

Can this M8 sensor go on a new machine BOM?

Can this sensor go on a new machine BOM? Yes. Both lifecycle status and product status read Active, with no conflicting lifecycle signal, so new design-in is reasonable. EU RoHS compliance is listed, but no directive revision is stated.

The termination matters: cable leads, not a connector. Put that detail on the BOM with E2E-X3B1D8-R 5M; “Box” describes the packaging, not how the sensor connects to the machine.

The 3mm target gap sets the mounting decision

The listed 3mm sensing distance leaves little room for uncertain target placement and does not establish detection at that gap for every target material. The stronger case is a compact, shielded inductive sensor in a threaded M8 body, provided the machine has the corresponding mount and a PNP-NO, 3-wire input.

The 10V–30V supply limits frame control-rail compatibility, not switching behavior at either edge. The -25°C to 70°C operating-temperature range bounds temperature fit; IP67 and IP69K are the listed ingress ratings. None settles target geometry.

What does the 1kHz response figure buy?

1kHz is the listed response frequency, not a switching-time measurement. It's a ceiling for assessing a repeating detection task, but it does not establish the timing of an individual transition at the controller input.

What still blocks the M8 installation?

Nor does that frequency figure finish the wiring or mount. The pinout and dimensioned drawing are absent, so the cable leads cannot be assigned to controller terminals and the threaded body cannot be cleared against the bracket from this page alone.

The output load-current limit is also absent; without it, the PNP output cannot be checked against the intended input load. A sensing-distance chart by target material would address the other open question raised by the 3mm figure. Get those items before fixing the bracket and input circuit.

View the Win-Source product page for E2E-X3B1D8-R 5M.

Key Takeaways for Engineers & Buyers

  • Check target placement against the listed 3mm sensing distance.
  • Keep the control rail within the listed 10V–30V supply limits.
  • Get the M8 drawing and cable-lead pinout before releasing the mounting and wiring.