3mm sensing, 10V to 30V supply limits and a threaded M8 body set the initial fit.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR INDUCT 3MM PNP M8 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
The 3mm reach decides whether this sensor gets a trial
Target placement is the first constraint. The 3mm sensing-distance ceiling calls for a trial with the intended target; it isn't a guarantee that every target will switch at that gap. The listed 10V to 30V supply limits bound the rail choice, not excursions outside that range.
Omron lists E2E-X3B1T8 2M as Active, with no conflict among its lifecycle signals. New design-in is reasonable if the target test passes. EU RoHS compliance is listed.
PNP-NO rules out the wrong controller input
An NPN controller input is the wrong destination for this PNP-NO, 3-wire sensor. For a matching input, the shielded, threaded M8 body and cable leads make sense at a machine-mounted detection point where the target can be held within the listed 3mm sensing-distance ceiling. The listed 1kHz response frequency is a ceiling, not proof that the installed target will be detected at every event rate below it.
Ingress ratings help; switching and wiring details remain open
The output-current limit is missing. PNP-NO tells you how the output switches, not what load it can drive. The listed IP67 and IP69K ingress ratings strengthen the case for a machine-mounted sensor exposed to washdown, but they do not establish resistance to a particular process fluid. The operating-temperature range of -25°C to 70°C bounds the ambient check; a location outside it is not covered by that range.
Get the output-current limit, switching hysteresis and cable-lead wiring diagram before fixing the bracket or input circuit. None appears here. Without them, the load, target motion and harness cannot be signed off on the ratings above.
Can the line keep using the cable-lead version?
Can the line keep using E2E-X3B1T8 2M? Its lifecycle fields agree on Active status. The production constraint is its cable-lead termination, not a lifecycle warning. Put the lead-termination step in the work instruction for this boxed part; a running line shouldn't depend on an assumed connector.
View the Win-Source product page for E2E-X3B1T8 2M.
Key Takeaways for Engineers & Buyers
- Test the intended target against the 3mm sensing-distance ceiling.
- Check the event rate against the listed 1kHz response-frequency ceiling.
- Get the cable-lead wiring diagram before releasing the harness.