3mm sensing distance, 10V ~ 30V supply limits, and an M8 threaded body set the fit.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR INDUCT 3MM PNP M8 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
Active status makes this M8 sensor a new-design candidate
And the lifecycle signals agree: E2E-X3B1T8 5M is Active and a candidate for new designs as well as existing production. EU RoHS compliance is listed, though no revision is stated. Those statuses do not settle installation: the shielded inductive sensor’s M8 threaded body must fit the mount, while its PNP-NO, 3-Wire output and cable leads must match the input and harness.
The 3mm sensing limit puts target placement first
This part is wrong for targets that cannot stay within its listed 3mm sensing distance. It fits where a shielded, M8 threaded sensor can sit close to the target and feed a PNP-NO input. The 3mm figure is a placement limit, not proof of detection at that gap with every target material.
The listed 10V ~ 30V supply range puts 30V at the ceiling; it says nothing about tolerance to supply transients. The listed 1kHz response frequency is a ceiling, not a guarantee that a particular short event will register. Operating temperature is listed from -25°C ~ 70°C, with 70°C the upper bound; that does not settle temperature rise at the mounted sensor.
The PNP output still needs its load limit
The missing output load-current rating is the weak point, even though PNP-NO specifies the switching behavior. The input-load check remains open. The wiring diagram and dimensional drawing are also absent, leaving cable connections and mounting clearance unresolved.
Cable leads are the running-line buying constraint
The M8 thread constrains mounting before an order is placed; cable leads fix the harness interface. Keep E2E-X3B1T8 5M on the BOM with cable-lead termination explicit. A connector-ended sensor won’t meet the same harness arrangement. Box packaging is listed but doesn’t change the interface. For existing production, Active status gives no reason here to plan a migration, while exact termination still needs protection against an ordering error.
View the Win-Source product page for E2E-X3B1T8 5M.
Key Takeaways for Engineers & Buyers
- Place the target against the listed 3mm sensing limit, not an assumed larger gap.
- Match the control input to the PNP-NO, 3-Wire output.
- Keep cable-lead termination explicit on the BOM.