3mm sensing, 10V ~ 30V supply limits, an M8 barrel and PNP-NC output set the installation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR INDUCT 3MM PNP M8 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
Does the active E2E-X3B28-M5 belong on a new BOM?
Can we put this on a new machine BOM? Yes. E2E-X3B28-M5 has aligned Active lifecycle and product-status signals, so new design-in is reasonable if its sensing geometry and output suit the machine. EU RoHS compliance is listed.
That verdict does not make the sensing position interchangeable. The controller must accept the PNP-NC output, and the target must be detectable at the required distance.
3mm sensing distance sets the target geometry
3mm is the listed sensing distance, not proof that every metal target will switch at that gap. Check the actual target and mounting arrangement before fixing the sensor position; a missed target becomes a missed machine event.
30V is the supply ceiling, not a suggested rail setting. The listed lower bound is 10V. Those limits screen the controller supply but say nothing about the load the output can drive. A supply outside that range rules out the installation even if the barrel fits.
PNP-NC must match the controller input
Even at the right distance, detection is useful only if the controller interprets the output correctly. The PNP-NC, 3-wire configuration calls for a matching input and logic expectation; treating it as normally open gives the machine the wrong signal state.
The listed 1kHz response frequency can screen moving-target applications. It can rule out one that demands more frequent events, but it can't establish the timing of a pulse at the controller.
IP69K helps, but the M8 installation still needs work
The connector-terminated interface is the weak point. IP67 and IP69K make wet machine locations plausible, but neither rating establishes chemical compatibility for the nickel-plated brass body or makes a location outside the -25°C ~ 70°C operating-temperature range acceptable.
The shielded, threaded M8 cylinder belongs at a metal-target station with a matching mount, not at a nonmetal-target station or in a different barrel thread. Box is the listed packaging; specify the mating connection separately rather than assuming a harness comes with the sensor. Keep the connector and mounting callouts on the BOM for a running line: a mechanical mismatch can stop assembly even when the electrical limits fit.
What remains unknown at the connector and target?
The installation isn't closed. The connector pinout and dimensioned M8 drawing are absent. So are an output-load limit and target-dependent sensing data. Get them before releasing the harness, mount or detection margin.
View the Win-Source product page for E2E-X3B28-M5.
Key Takeaways for Engineers & Buyers
- Check detection on the actual metal target at the listed 3mm distance.
- Match the controller input to the PNP-NC, 3-wire output.
- Keep the sensor supply within the listed 10V ~ 30V range.