3mm sensing distance, 10V ~ 30V supply boundaries and an M8 threaded body with cable leads.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR INDUCT 3MM NPN M8 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
Active status supports a new inductive-sensor design-in
Cable leads complicate sensor swaps. The lifecycle is less troublesome: Omron E2E-X3C18 2M is marked Active across the listed status fields, supporting new design-in. It is also listed as EU RoHS compliant. For existing production, keep the termination method in the build instructions so a replacement sensor does not sit unused while the line waits for someone to work out the connection.
The 3mm target gap deserves attention before the supply rail
3mm is the listed sensing-distance limit, not a gap to assume will work with every target. Check the placement first: a target that cannot approach within that distance rules it out. The 10V ~ 30V supply range sets the electrical boundaries; 30V is a ceiling, not a working setpoint to aim for. The stated operating-temperature range is -25°C ~ 70°C, with no listed coverage outside those endpoints.
An M8 body and NPN-NO output narrow the fit
The fit is specific. This metal-target sensor has a shielded, threaded M8 body for a compact machine mounting point, but its 3-wire NPN-NO output must also match the input circuit. IP67 and IP69K are listed ingress ratings for the sensor, not for an exposed cable termination at the installation. An input expecting different output behavior presents a wiring mismatch, even if the body fits the hole.
Will the line accept cable leads instead of a connector?
Will the line accept cable leads instead of a connector? E2E-X3C18 2M is listed with cable leads and Box packaging, not a separable connector termination. That distinction affects both buying and maintenance. Put the lead-routing and termination method in the assembly instruction before releasing the sensor for production; otherwise, a maintenance swap becomes an on-machine wiring task with room for an inconsistent repair.
The nickel-plated brass, threaded body defines the mounting style, but it does not show where the cable can bend after leaving the sensor. Leave room in the machine layout to route and protect that exit. The listed ingress ratings apply to the sensor, not to a field splice. With the cable work defined, this is a manageable sustaining part. Without it, electrical fit alone won’t keep a running line moving.
The 1kHz figure does not close switching behavior
1kHz is the listed response-frequency limit, not a turn-on or turn-off delay. Switching timing, an output load-current limit, hysteresis and a dimensioned cable-exit drawing are absent from the listing. Those gaps matter to the input circuit and mounting station.
View the Win-Source product page for E2E-X3C18 2M.
Key Takeaways for Engineers & Buyers
- Set the target-gap review against the listed 3mm sensing distance.
- Match the machine rail to the 10V ~ 30V supply boundaries.
- Put cable-lead termination in the M8 sensor replacement instruction.