10V ~ 30V supply, 3mm sensing distance, threaded M8 body and cable leads.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR INDUCT 3MM NPN M8 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
The supply rail sets the first boundary
The control rail has a hard ceiling. The 10V ~ 30V supply range can settle the rail choice for E2E-X3C18 5M, but 30V is an upper bound rather than a working target, and the range says nothing about the load the output can drive. The lifecycle and product statuses agree on Active, supporting new design-in when the sensing geometry fits. EU RoHS compliance is listed.
The M8 body does not buy more sensing reach
But can the target pass close enough? The shielded, threaded M8 body suits a machine bracket facing a passing metal target. Its listed 3mm sensing distance is a reach ceiling, not clearance to spend on bracket error and target travel.
The NPN-NO, 3-wire output must match the intended input. The 1kHz response frequency screens switching demand but does not specify sensing latency. IP67 and IP69K are listed for the sensor; neither settles protection at the cable termination. Put the sensing face and cable route on the machine layout before committing the mounting position.
Cable leads matter at the 70°C boundary
70°C is the upper operating-temperature bound, ruling out a sensing-head location above it. Cable leads, rather than a specified connector, make termination planning part of the installation. Set the cable route before fixing the M8 bracket.
The NPN-NO hookup still needs its drawing
The hookup isn't settled. The wiring diagram and output-current limit are absent, so the NPN-NO output cannot yet be assigned to an input with a confirmed load budget. A dimensioned mounting drawing and sensing-distance-versus-target-material curve are also absent; the M8 thread and 3mm limit alone cannot close the mechanical layout.
View the Win-Source product page for E2E-X3C18 5M.
Key Takeaways for Engineers & Buyers
- Keep the supply within 10V ~ 30V; 30V is the upper bound.
- Set target travel against the 3mm sensing-distance ceiling.
- Route the cable leads before fixing the M8 mounting position.