Omron E2E-X3C18-M1: Active for New Machine Designs

E2E-X3C18-M1 Omron product image

3 mm shielded sensing, 10 V to 30 V supply and M8 mounting for NPN-NO inputs.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 3MM NPN M8 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V

Is this M8 sensor a new-design choice?

Can I specify this sensor for a new machine? Yes. Omron marks E2E-X3C18-M1 Active across the lifecycle, product-status and parameter fields, with no conflicting status, so it supports new design-in rather than a sustaining-only purchase. EU RoHS is listed as compliant.

The connector termination on the threaded M8 body matters more than Box packaging: specify the mating harness before releasing the BOM. Its NPN-NO, 3-wire output cannot directly match an input wired for different switching behavior. The mechanical mount and electrical input both need to fit, or installation stops.

The 3 mm reach sets the target gap

The reach is short. The listed 3 mm sensing distance sets the target-gap decision; it doesn't establish how every target material behaves at that gap. A machine rail outside the 10 V to 30 V operating range rules out this sensor without a supply change.

The listed 1 kHz response frequency is a speed boundary for screening, not proof that a particular moving target will be detected. The -25°C to 70°C operating-temperature range sets the ambient boundary but leaves temperature at the installed sensor open.

Shielding helps the M8 mount, not the input match

A misplaced target can defeat the 3 mm reach. The shielded, threaded M8 body, though, gives a compact mounting format for a machine bracket. Its inductive sensing and NPN-NO output belong with suitable metal targets and a matching machine input, not a channel expecting the opposite output behavior.

IP67 and IP69K are listed ingress-protection ratings. They help screen the sensor for a demanding enclosure environment but do not establish the protection of the completed connector installation.

What remains open at the connector?

The 10 V to 30 V supply range makes wiring errors consequential. Connector pinout, mating-connector drawing and output load-current rating are absent. Obtain them before freezing the E2E-X3C18-M1 harness and input circuit.

View the Win-Source product page for E2E-X3C18-M1.

Key Takeaways for Engineers & Buyers

  • Set the target gap against the listed 3 mm sensing distance.
  • Match the machine input to NPN-NO, 3-wire switching.
  • Keep the sensor supply within its 10 V to 30 V operating range.