Omron E2E-X3C1L8 5M: Active for New Sensor Designs

E2E-X3C1L8 5M Omron product image

3mm sensing ceiling, 10V ~ 30V supply, threaded M8 body, and cable leads.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 3MM NPN M8 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V

The 3mm ceiling still permits new design-in

The 3mm sensing-distance ceiling limits the target gap; this is no fix for a loose mechanical gap. E2E-X3C1L8 5M is Active across the lifecycle fields, so new design-in is reasonable. EU RoHS compliance is stated.

Cable leads, not an M8 connector, drive the build step

Does it have a connector? No. The specified cable leads need a wiring step at assembly; the M8 thread describes the sensor body, not an electrical connector. Put the termination on the build sheet when ordering E2E-X3C1L8 5M. Mistaking the thread for a mating connector would leave the station unable to wire the sensor. Box packaging does not change that task.

The 10V ~ 30V rail is only the starting gate

10V ~ 30V is the listed supply operating range. A rail outside it rules the sensor out; neither endpoint is a preferred setpoint. The listed 3mm sensing distance is a ceiling, not permission to place the target exactly there without resolving installation geometry. The 1kHz response-frequency figure is also a listed ceiling: it can rule out faster target events but does not establish switching timing margin. Operating-temperature bounds of -25°C ~ 70°C screen the installation environment; they do not establish sensing behavior at those bounds.

The M8 body does not settle target detection

It’s wrong for a nonmetal target or a controller expecting a different output topology. Inductive sensing and the NPN-NO, 3-wire output make it a candidate for a close-range metal-target station with the matching input. The shielded, threaded M8 body provides a mounting format, and IP67/IP69K addresses ingress exposure. Neither designation establishes the target gap or protects a cable connection by itself.

The listing has no switching-hysteresis or target-material correction data. Both gaps matter before setting a repeatable trip point. It also lacks a body drawing and wire identification, leaving the mechanical envelope and electrical connections unresolved; obtain those details before releasing mounting and wiring instructions.

View the Win-Source product page for E2E-X3C1L8 5M.

Key Takeaways for Engineers & Buyers

  • Keep the target inside the listed 3mm sensing ceiling; resolve hysteresis before setting the trip gap.
  • Keep the sensor supply within its 10V ~ 30V operating range.
  • Put the cable-lead termination on the M8 station build sheet.