Omron E2E-X3C1L8-M1: Active for New Industrial Designs

E2E-X3C1L8-M1 Omron product image

3mm sensing, 10V ~ 30V supply limits and an M8 thread set the fit; 1kHz alone does not settle timing.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 3MM NPN M8 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V

Active status supports a new E2E-X3C1L8-M1 design-in

The status is clear. Omron lists E2E-X3C1L8-M1 as Active across its lifecycle fields, with no conflicting status; the design-in decision turns on machine fit, not an end-of-life notice. EU RoHS compliance is listed.

The inductive sensor has an NPN-NO, 3-Wire output. It isn't a general-purpose answer to every proximity problem: the input circuit must accept that output, and a metal target must pass close to the sensing face.

The 3mm reach sets the first mechanical limit

Reach is the first constraint. The listed 3mm sensing distance is a ceiling, not a guaranteed gap for every target; beyond it, detection may be missed. The 10V ~ 30V supply limits bound rail choice but do not settle voltage tolerance at the sensor. The -25°C ~ 70°C operating-temperature range excludes locations outside its endpoints.

Will the M8 body and connector match the machine?

Will it fit the mount and connector? E2E-X3C1L8-M1 has a threaded M8 cylinder for a compact machine-mounted detection point; a bracket sized for another body may lack the opening or clearance it needs. The sensor is shielded and has an LED indicator, but neither solves a clearance problem. Match the installed connector and the NPN-NO, 3-Wire input before releasing a build. Box packaging doesn't identify the mating connector.

IP67 and IP69K are listed for the sensor. They matter where the installation faces ingress or washdown, but they do not establish protection at an assembled connection. A connector mismatch can still stall an otherwise straightforward change on an existing production line.

What still prevents a final machine-fit decision?

That leaves the pinout unresolved; it is absent here. A mechanical drawing is also missing, so the M8 thread alone cannot settle installed clearance. Without an output-load limit, the NPN output cannot be checked against the intended input load. The listed 1kHz response frequency does not define the shortest detectable event because switching-time conditions are not given.

View the Win-Source product page for E2E-X3C1L8-M1.

Key Takeaways for Engineers & Buyers

  • Test the intended metal target within the listed 3mm sensing distance.
  • Check the machine supply against the 10V ~ 30V listed limits.
  • Match the M8 mounting space and connector before releasing the build.