3mm sensing distance, 10V ~ 30V supply limits, M8 threaded body, -25°C ~ 70°C operation
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR INDUCT 3MM NPN M8 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
The 3mm gap decides placement before the housing does
A 3mm sensing distance and 10V ~ 30V supply bounds constrain placement and rail selection before housing ratings enter the decision. Treat 3mm as the listed sensing distance, not spare travel: a bracket that lets the target move beyond it can turn a reliable count into a missed one.
The 30V end is a supply ceiling, not a preferred rail; 10V is the lower listed bound. Neither limit settles the voltage that reaches the sensor after wiring losses. The listed 1kHz response frequency provides a first check against a fast-moving target, but it doesn't establish detection of a particular feature at line speed.
Active status supports a new sensor position
New design-in is defensible. Omron lists E2E-X3C1L8-M5 as Active, with no conflict among the lifecycle signals. Its inductive, shielded construction suits a position where a metal target passes close to the threaded body. Its NPN-NO, 3-wire output rules out a direct connection to an input expecting PNP behavior. EU RoHS compliance is listed. None of those facts establishes the target gap on the actual machine.
The M8 body fits a harsh location, not every input
70°C is the upper end of the stated operating range. Check temperature at the sensor position rather than assuming the enclosure temperature represents it. The M8 threaded, nickel-plated brass body gives the mounting plan a defined form, while IP67 and IP69K are listed ingress ratings for evaluating the location. Connector termination makes the mating interface part of the installation plan. This close-range sensor cannot span an uncertain machine gap.
What must the running line match?
Will the installed cable mate with this connector? E2E-X3C1L8-M5 is listed with connector termination and box packaging. Match the mating hardware before releasing a replenishment BOM; Active status does not correct a connector mismatch.
The 3mm claim still needs target evidence
3mm is the sensing distance to test against the real target. Without target-material sensing curves, the listing cannot settle the mounted detection gap. The connector pinout, output load-current limit, and mechanical drawing are also absent. Those details decide whether the input can be driven and whether the threaded body and connector clear the machine hardware.
View the Win-Source product page for E2E-X3C1L8-M5.
Key Takeaways for Engineers & Buyers
- Check the target gap against the listed 3mm sensing distance.
- Keep the supply within the listed 10V ~ 30V bounds.
- Match the connector mating hardware before releasing the BOM.