Omron E2E-X3C28-M1: Active for New Industrial Designs

E2E-X3C28-M1 Omron product image

3mm sensing distance, 10V to 30V supply bounds, threaded M8 body and NPN-NC output.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 3MM NPN M8 NC
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V

A shielded M8 pickup for a new NPN-NC station

So it belongs on a new industrial sensor BOM, not a migration list: the lifecycle fields agree on Active, and EU RoHS compliance is stated. E2E-X3C28-M1 is a shielded inductive pickup with a threaded M8 mount and an NPN-NC, 3-wire output. The listed 3mm sensing distance starts the target-gap test, but it doesn't guarantee switching at that gap for every target. A bracket adjustment won't fix a controller expecting a different output state.

The nickel-plated brass body and IP67/IP69K ratings make the sensor worth considering at an exposed station, but those ratings do not establish how the installed connector performs under washdown. Check the actual connection on the machine.

The supply ceiling is 30V, not a target

The rail has to fit. The supply runs from a 10V lower bound to a 30V ceiling; a rail outside that window rules out the installation. The operating-temperature range runs from -25°C to a 70°C ceiling, so check cabinet heat and cold startup against those limits.

What does the 1kHz response frequency settle?

1kHz is the listed response-frequency ceiling, not a promise that every brief passing target will produce a usable controller pulse. Fast detection is on the table, but the timing at the input remains open. The LED helps locate a switching point during setup; it cannot tell whether the controller caught the transition.

Will the connector match the running line?

Will the installed harness mate with this sensor? E2E-X3C28-M1 is listed as boxed and connector-terminated, but mating details are absent; match the connection before ordering for existing production. The datasheet still has to supply the connector pinout, output load-current limit, sensing-distance test conditions and response-time waveform. Without them, the electrical and timing checks remain open.

View the Win-Source product page for E2E-X3C28-M1.

Key Takeaways for Engineers & Buyers

  • Test the listed 3mm sensing distance with the installed target and bracket.
  • Keep the supply within the listed 10V to 30V bounds.
  • Match the NPN-NC, 3-wire output to the controller input before release.