3mm sensing distance, M12 threaded body, 10V to 30V supply limits, and cable leads.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 3MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
The 3mm reach makes mounting the first decision
A 3mm sensing distance on an M12 threaded body makes target placement the first constraint. The shielded inductive head belongs at a metal target in a threaded machine mount; it isn't for detecting nonmetal objects. E2E-X3D1-N 10M has aligned Active lifecycle signals, making it a candidate for new industrial designs rather than a sustaining-only choice. EU RoHS compliant.
Bulk packing needs a cable-handling plan
Bulk packaging is the weak point for a cable-lead sensor, even with Active lifecycle status. It does not specify how the attached lead is protected during assembly; set a receiving and cable-handling method for the M12 threaded body before line release.
Supply limits and response rate narrow the machine fit
30V is the listed supply ceiling, not a working setpoint. The lower listed bound is 10V; keep the machine supply within those limits without treating either endpoint as a margin. The listed 1kHz response frequency can screen the event rate, but it doesn't specify switching delay at the installed target, and the 2-wire NPN-NO output still needs a compatible machine input regardless of mechanical fit.
Operating temperature runs from -25°C to 70°C. Those bounds determine whether the mounting location qualifies, not how much heat the installation can add. IP67 supports an exposed machine location but says nothing here about sealing a field cable connection.
The output and target still need missing details
The wiring case remains open. The datasheet wiring diagram, off-state leakage, residual output voltage, and target-material correction data are absent here. Those details decide whether the 2-wire NPN-NO output works with the intended input and whether the actual metal target triggers at the planned position. Get them before fixing the wiring or mount.
View the Win-Source product page for E2E-X3D1-N 10M.
Key Takeaways for Engineers & Buyers
- Set the target position against the listed 3mm sensing distance.
- Match the machine input to the 2-wire NPN-NO output.
- Check enclosure temperature against the 70°C operating limit.