3mm sensing distance, 10V ~ 30V supply, threaded M12 body; discontinued.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 3MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
New inductive stations should not start with this sensor
New stations are the wrong place for this discontinued sensor. It’s a sustaining-design part where its shielded, threaded M12 body and cable leads already match the installation. One lifecycle signal says EOL; both lifecycle and product statuses say Discontinued. Neither supports a new design-in. EU RoHS compliance does not change that.
The 3mm target gap decides the mechanical fit
3mm is the listed sensing-distance ceiling. If the target can move beyond that gap, detection cannot be counted on, and the listing provides no target-dependent sensing curve to settle a marginal installation. The shielded inductive format and threaded M12 body suit an existing metal-target station, not a different mounting arrangement.
The 10V ~ 30V supply range sets the electrical boundary. Treat 30V as the upper ceiling, not a preferred rail; a circuit outside the stated range is not covered by the listing. Its 2-wire NPN-NO output must match the input circuit. The stated operating-temperature range is -25°C ~ 70°C, but the listing says nothing about temperature effects on sensing distance.
Bulk packing changes how the M12 sensor reaches the line
M12 identifies the threaded body. Bulk packaging and cable leads set the handling and termination work for existing production. Secure inventory for E2E-X3D1-N3 and plan migration rather than extending its use to another station.
The connection and mounting details still need the datasheet
The 3mm ceiling leaves a marginal target gap unresolved without a target-dependent sensing curve. The listing also gives no wiring diagram, output load-current limit or mechanical drawing. A 2-wire NPN-NO description cannot settle the connection, and M12 alone cannot establish installed dimensions.
View the Win-Source product page for E2E-X3D1-N3.
Key Takeaways for Engineers & Buyers
- Keep E2E-X3D1-N3 off new-design BOMs; plan migration for existing production.
- Check the target gap against the listed 3mm sensing-distance ceiling.
- Match the 2-wire NPN-NO connection to the existing input circuit before wiring.