3mm sensing distance, 10V ~ 30V supply limits, M12 threaded body, -25°C ~ 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 3MM CYL 2M |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
Active status supports a new inductive-sensor design
Design it in. E2E-X3D1-R 2M has matching Active lifecycle signals and no listed conflict, so its status does not confine it to sustaining designs. EU RoHS compliance is listed.
Bulk packaging calls for line handling. Plan cable-lead termination before releasing the sensor into a build; it won't follow the same assembly flow as a board-mounted part.
A 3mm target gap decides whether the M12 body fits the job
This sensor is wrong for a target that cannot come within its listed 3mm sensing distance. The figure is a limit, not a promise that every target will switch at 3mm; target material and mounting geometry still matter. Where the target path allows that clearance, the shielded M12 threaded body gives the machine builder a defined mounting format, but IP67 ingress protection does not settle whether the sensing face can sit close enough to the moving part.
The controller input must suit a 2-Wire NPN-NO sensor
Even with the target in reach, a mechanical fit is not enough: the controller input must work with NPN-NO, 2-Wire switching. E2E-X3D1-R 2M lists 10V as the lower supply limit and 30V as the upper ceiling. Those bounds let you screen the control rail, not approve rail transients or the input circuit.
The stated operating-temperature range runs from -25°C to a 70°C ceiling. A mounting location outside that range is out of scope for this listing. Inside it, the electrical and sensing checks still stand. The 2M cable description and cable-lead termination put the connection at the sensor location rather than on a board.
1kHz leaves the target and wiring checks open
1kHz is the listed response-frequency limit, not a guarantee for every passing target. Without target-material correction data or a dimensioned drawing, the effective sensing gap and mounting clearance remain open. The absent wiring diagram and off-state leakage specification matter to the 2-Wire controller input.
View the Win-Source product page for E2E-X3D1-R 2M.
Key Takeaways for Engineers & Buyers
- Check target travel against the 3mm sensing-distance limit.
- Match the 2-Wire NPN-NO output to the controller input.
- Plan line handling for bulk-packed sensors with cable leads.