3mm sensing, 10V ~ 30V supply, M12 threaded body; discontinued status limits it to sustaining designs.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 3MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
The 3mm reach decides the bracket before the wiring
3mm is the listed sensing distance. Set target travel before fixing the bracket, but don't assume that distance applies to every target material or approach angle. The 10V ~ 30V supply range defines the permitted rail; it says nothing about the load the controller input can present.
The listed 1kHz response frequency warrants a closer look at switching behavior where machine features pass quickly, but it doesn't establish that a particular short event will register. A sensor can power up normally and still miss a target, leaving the controller without that event.
Discontinued status confines this sensor to existing production
No new design-in. E2E-X3D1-R 5M has Discontinued lifecycle and product statuses alongside an EOL signal; the label conflict doesn't change the decision. Secure inventory for existing production and plan migration. Bulk packaging calls for a line-handling check. EU RoHS is marked compliant.
The M12 body fits fixed mounts, not every input circuit
A long-reach target or a controller expecting a different input scheme is the wrong job for this sensor. Its NPN-NO, 2-Wire output needs an input designed for that topology; a wrong wiring assumption can leave the machine blind to target passage. The M12 threaded, shielded cylinder with cable leads suits a fixed machine mount. IP67 and the -25°C ~ 70°C operating range describe the stated environmental fit. Neither establishes that the cable will tolerate repeated flex.
The output circuit and installed envelope remain unresolved
The absent output load-current limit is the weak point, though the stated NPN-NO, 2-Wire topology identifies the input circuit to investigate. Output voltage drop and pinout are also absent, leaving input thresholds and wiring unresolved. Without a mechanical drawing, the M12 thread designation does not establish the full installed envelope. Get those items from the datasheet before releasing wiring or mounting details.
View the Win-Source product page for E2E-X3D1-R 5M.
Key Takeaways for Engineers & Buyers
- Set target travel against the listed 3mm sensing distance before fixing the bracket.
- Match the 10V ~ 30V supply range to the controller rail.
- Secure inventory for existing production and plan migration; status is Discontinued.