3mm sensing distance, 10V ~ 30V supply bounds, M12 thread and 5M cable set the installation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUC 3MM CYL 5M CBL |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Voltage - Supply: 10V ~ 30V |
The 3mm reach makes target placement the first decision
3mm is the listed sensing distance. It is not a guaranteed gap for every target and mounting arrangement. For E2E-X3D15-N 5M, the first question is whether the mechanism can bring the target close enough; if it cannot, the electrical interface is beside the point.
The listed 10V ~ 30V bounds let you check the intended supply against the sensor's limits, but they do not establish output behavior at either end. The controller input and wiring scheme must also suit the NPN-NO, 2-Wire output.
Can this active sensor go on a new production BOM?
Can we put it on a new production BOM? On lifecycle grounds, yes: E2E-X3D15-N 5M is marked Active throughout the lifecycle fields. Compliance is the hold. One field says RoHS Compliant; another says RoHS Non-Compliant. Resolve that conflict before releasing a build that requires EU RoHS compliance.
Bulk packaging and cable leads make line preparation the buying constraint. Set the cable-termination process for the listed 5M lead before committing the assembly flow; this is not a connectorized sensor that can be plugged in at the station.
The M12 mount fixes more than the sensor position
A threaded mount and a routed lead constrain the installation. The M12 threaded cylinder and 5M cable suit a fixed machine location with a planned cable path, but they're a poor match for an installation that depends on disconnecting the sensor at the body.
The shielded inductive sensor lists IP67 ingress protection. Its -25°C ~ 70°C operating-temperature range sets the ambient boundary to check at the mounting point. Neither figure rescues a target beyond the listed 3mm sensing distance.
The missing output details still block wiring sign-off
And the electrical checks remain unfinished. Response frequency is absent, so sensing distance alone cannot establish whether a moving target will be detected in time. Get the wiring diagram, output voltage-drop and leakage limits, and dimensional drawing before closing the controller input and mount.
View the Win-Source product page for E2E-X3D15-N 5M.
Key Takeaways for Engineers & Buyers
- Check the target and mounting gap against the listed 3mm sensing distance.
- Match the controller input to the NPN-NO, 2-Wire output before wiring the 5M cable.
- Resolve the conflicting RoHS entries before a compliance-dependent release.