3mm sensing distance, 10V–30V supply, M12 threaded body; EOL status rules out new design-in.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 3MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
The 3mm reach does not justify a new design-in
3mm is the listed sensing distance. Set the target geometry with that reach in mind, but do not treat it as an installation tolerance. E2E-X3D1S-M1 belongs in sustaining designs only: its lifecycle fields say EOL even though Product Status says Active.
That conflict doesn't make Active a safe assumption for a new machine. EU RoHS compliance addresses a separate question and does not change the lifecycle decision.
The 30V supply ceiling sets a hard rail boundary
Keep the rail inside bounds. The listed supply range runs from a 10V lower limit to a 30V ceiling; neither is a preferred operating setpoint. The -25°C to 70°C operating-temperature range bounds the installation environment, not performance beyond it.
A close metal target fits; a different input topology does not
A control input requiring a different output topology rules this sensor out: NPN-NO, 2-Wire is the only output listed. Its shielded, M12 threaded body belongs at a close target on a machine frame, where the 3mm sensing distance can be accommodated.
The 1kHz response-frequency rating is a ceiling, not a promise that every event at that rate will be detected. IP67 describes the listed ingress protection; it does not establish how a particular installed connector will seal.
Bulk packing is manageable; the missing interface details are not
Bulk packaging is awkward for sustaining builds, but the M12 thread and connector termination at least identify what the running line has to match. A connector label isn't a mating specification. Without the connector pinout, the existing harness cannot be checked against the sensor contacts from this page.
A dimensioned drawing is also absent: M12 identifies the thread, not body length or clearance at the connector. Output leakage and on-state voltage drop are absent, leaving the control input’s off-state and on-state margins unresolved for this 2-Wire output. Resolve those gaps before committing another build to E2E-X3D1S-M1. Secure inventory for existing production and plan migration.
View the Win-Source product page for E2E-X3D1S-M1.
Key Takeaways for Engineers & Buyers
- Check the installed target gap against the 3mm sensing distance.
- Keep the supply between the listed 10V and 30V limits.
- Obtain the connector pinout before approving the existing harness.