3mm sensing, 10V–30V supply limits and an M12 threaded body set the first fit checks.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 3MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 2-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
Active status supports a new E2E-X3D2-M1 design-in
Active status can't settle machine fit, but every listed lifecycle signal marks E2E-X3D2-M1 Active, with none indicating a sustaining-only restriction. It remains a candidate for new design-in, subject to sensing, electrical and mechanical fit. EU RoHS is compliant.
The 3mm reach sets the target geometry
That still leaves the target geometry. The listed 3mm sensing distance is a reach limit, not a promised switching point at every mounting position; a target beyond it can leave the input unchanged when the machine expects detection.
The 10V–30V limits bound the supply rail, not the output load. The operating-temperature range is -25°C to 70°C, with 70°C a ceiling for placement near heat rather than a preferred working temperature. The listed 1kHz response frequency helps screen a fast detection requirement, but does not establish switching behavior for the actual target.
Bulk packing needs a line-side plan
How will bulk-packed E2E-X3D2-M1 reach the assembly station? Bulk is the listed package, so set a line-side handling method before the sensor goes into production. Its connector termination doesn't establish a feeder-ready presentation for the assembly station.
The M12 body still needs connection details
Wrong for inputs that cannot accept NPN-NC, 2-wire signaling, this sensor needs a matching input. Obtain the absent connector pinout, output load limit and dimensioned mounting drawing from the datasheet before releasing the harness and threaded M12 installation.
View the Win-Source product page for E2E-X3D2-M1.
Key Takeaways for Engineers & Buyers
- Check target spacing against the listed 3mm sensing distance.
- Keep the supply within the listed 10V–30V limits.
- Plan line-side handling for Bulk packaging.