3mm sensing distance, 10V–30V supply limits and a threaded M12 body
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 3MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 2-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
Active status supports a new E2E-X3D2-N design-in
The part is Active. The lifecycle fields agree, and the part is marked compliant with EU RoHS. The NPN-NC, 2-wire output still has to match the intended input before E2E-X3D2-N goes onto a running line.
The 10V–30V supply limits do not settle transients
10V to 30V is the listed supply range. Its upper limit is a ceiling, not a nominal rail to design around. A control supply outside that range rules out a direct connection, while the range doesn't describe excursions at the sensor leads.
The stated operating-temperature range is -25°C to 70°C. It lets you screen the mounting location against expected ambient conditions, but it does not establish how sensing distance changes across that range.
A 3mm sensing limit puts target placement first
3mm is the listed sensing distance. E2E-X3D2-N is worth considering for close-range metal detection, not for a target that must be detected beyond that limit. The shielded, threaded M12 body gives a defined mounting format. Its nickel-plated brass body and IP67 rating inform the enclosure choice, though neither establishes whether the installed cable entry preserves that protection.
The listed 1kHz response frequency is a ceiling for screening event rates, not proof that a particular moving target will be detected. The NPN-NC, 2-wire output fixes the kind of input circuit this sensor needs. Get that interface wrong and an otherwise suitable mounting position won’t produce a usable signal.
Wiring and target behavior remain open
The missing wiring diagram leaves cable connection unresolved, although the NPN-NC, 2-wire designation identifies the circuit to check. A mounting drawing is also absent; the M12 thread designation does not give the dimensions needed to release the bracket.
Target-dependent sensing data is absent as well. That gap matters most when the intended detection point sits near the listed 3mm limit.
Will bulk packaging work on this sensor line?
How will the line handle cable leads? Bulk is the stated packaging, and cable leads are the stated termination. Plan how the line will handle and route them rather than assuming a connectorized installation. Active status supports continued use in existing production, but the packaging and termination still have to fit the assembly process.
View the Win-Source product page for E2E-X3D2-N.
Key Takeaways for Engineers & Buyers
- Check the input circuit against the NPN-NC, 2-wire output.
- Check target-dependent sensing data before placing a target at the 3mm limit.
- Plan line handling for the bulk-packed sensor and its cable leads.