Omron E2E-X3D2L 2M: Active, but RoHS status conflicts

E2E-X3D2L 2M Omron product image

3mm sensing distance, 12V ~ 24V supply and threaded M12 body; RoHS status needs resolution.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors
PackageCylinder, Threaded - M12
Core functionSENSOR PROX
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NC, 2-Wire; Response Frequency: 1kHz; Voltage - Supply: 12V ~ 24V

Active status does not settle the RoHS conflict

The RoHS conflict is the weak point: the compliance field says compliant, while the specification list says non-compliant. Every lifecycle signal calls E2E-X3D2L 2M Active, with no evidence calling for a sustaining-only decision. A compliance-dependent release remains on hold, and new design-in is reasonable only after the conflict is resolved.

The M12 body fits a mounted sensing point

It's a mounted sensor. The threaded M12 body has cable leads, not board mounting; its shielded construction and IP67 listing support a mounted sensing-point assessment. The NC, 2-Wire output must suit the control input.

The 3mm gap matters more than the 1kHz headline

3mm is the listed sensing distance, not a guaranteed installed gap across target materials. Set the target and mounting clearance against that figure first: a missed target becomes a missed machine event. The 12V ~ 24V supply range defines the listed rail window, but doesn't establish output behavior at its edges.

The -25°C ~ 70°C operating-temperature range bounds the stated environment without settling performance across that range, while the listed 1kHz response frequency helps screen event rate but gives no switching-delay figure for timing a control sequence.

What holds up the bulk-packed sensor at release?

Nor do those limits settle release. Bulk packaging calls for a handling plan for the cable leads, and the RoHS conflict needs a definitive answer before E2E-X3D2L 2M goes onto a controlled BOM. Active status cannot resolve either issue.

The listing lacks a wiring diagram, dimensional drawing, output-current limit and target-dependent sensing curve. Without them, the numbers above cannot settle connection details, mechanical clearance or whether the proposed target will switch reliably.

View the Win-Source product page for E2E-X3D2L 2M.

Key Takeaways for Engineers & Buyers

  • Resolve the conflicting RoHS entries before releasing E2E-X3D2L 2M on a controlled BOM.
  • Test the target gap against the listed 3mm sensing distance.
  • Obtain the wiring diagram before connecting the NC, 2-Wire output.