Omron E2E-X3T1 5M: Active, Viable for New Design-In

E2E-X3T1 5M Omron product image

3mm sensing distance, M12 threaded body and SCR-NO, 2-Wire output set the fit.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M12
Core functionSENSOR PROX INDUCTIVE 3MM CYLIND
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 1kHz, 25Hz; Voltage - Supply: 20 VDC ~ 264 VDC (40 VAC ~ 264 VAC)

Active status permits a new design-in, but the output decides it

New design-in is viable. Omron E2E-X3T1 5M has aligned Active lifecycle signals and is marked EU RoHS compliant. The electrical gate remains: its SCR-NO, 2-Wire output needs a control input built for that switching arrangement. A fitting threaded body cannot make a different output type compatible.

The 3mm reach leaves little room for a misplaced target

Even with the electrical interface matched, target placement remains tight. The listed 3mm sensing distance sets the geometry, not a guaranteed pickup point for every metal target; working at its edge risks missed detections. The listed 20 VDC ~ 264 VDC (40 VAC ~ 264 VAC) supply bounds narrow the control circuits that can power the sensor, but say nothing about allowable output load. The -25°C ~ 70°C operating temperature range frames placement; it doesn't establish what the control input can tolerate.

SCR-NO wiring still needs its electrical limits

The load-current limit and off-state leakage are missing, although the output is identified as SCR-NO, 2-Wire. Without the wiring diagram and sensing-distance conditions, input compatibility and target clearance remain unresolved.

Can the line handle bulk cable leads?

Can the line handle bulk cable leads? Bulk packaging and cable leads make termination and handling assembly tasks, not connectorized drop-in work. The threaded M12 nickel-plated brass body provides a mounting path, but IP67 describes the sensor’s ingress protection; it can't establish a seal for the installed cable route.

The LED provides local indication. The listed 1kHz and 25Hz response frequencies have no stated conditions, so neither figure alone settles fast-target timing. Put bulk handling and cable termination in the work instructions before moving the Omron E2E-X3T1 5M into production.

View the Win-Source product page for E2E-X3T1 5M.

Key Takeaways for Engineers & Buyers

  • Set target clearance against the listed 3mm sensing distance; sensing conditions are not stated.
  • Match the 20 VDC ~ 264 VDC (40 VAC ~ 264 VAC) supply bounds to the control circuit.
  • Add cable termination for the bulk M12 sensor to the assembly instructions.