Omron E2E-X3T1: Active for New Inductive Sensor Designs

E2E-X3T1 Omron product image

3mm sensing distance, M12 threaded body, and 20 VDC to 264 VDC supply range

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M12
Core functionSENSOR PROX INDUCTIVE 3MM CYLIND
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 1kHz, 25Hz; Voltage - Supply: 20 VDC ~ 264 VDC (40 VAC ~ 264 VAC)

Active status leaves the sensing fit to decide

Active status clears the lifecycle hurdle. Omron E2E-X3T1 has consistent Active signals and is a candidate for new designs. EU RoHS compliance is listed without a directive revision; target geometry and electrical fit still decide adoption.

The supply range is clearer than the response rates

The response figures don't settle fast-target behavior: 1kHz and 25Hz appear without conditions that distinguish them. The supply limits are clearer. The specified range runs from 20 VDC to a ceiling of 264 VDC, or from 40 VAC to a ceiling of 264 VAC; a lower-voltage control rail falls outside it. The -25°C to 70°C operating-temperature range bounds installation conditions, not normal setpoints at either end.

A 3mm reach commits the bracket and the line

The 3mm sensing distance puts target clearance first. The shielded, M12 threaded nickel-plated-brass cylinder fits a close-range industrial metal-detection point only where that reach and mounting envelope work. The listed distance alone establishes no margin for every target.

Bulk packaging and cable leads put termination on the assembly line. Define the lead-termination process before releasing the build.

An SCR-NO input match still needs wiring evidence

A controller input expecting different output behavior is the wrong destination for an SCR-NO, 2-wire sensor, even if the M12 mounting fits. With a matching input and supply, E2E-X3T1 can serve a close-range metal-presence point, but its listed IP67 ingress designation does not establish the performance of the installed cable interface.

The load-current limit and off-state leakage are absent here, leaving input compatibility unresolved. The lead-wiring diagram and dimensional drawing are also absent, so lead identification and bracket clearance cannot be released from these facts alone. Get those items before freezing the wiring and mount.

View the Win-Source product page for E2E-X3T1.

Key Takeaways for Engineers & Buyers

  • Check the 3mm reach against the actual target and clearance.
  • Match the SCR-NO, 2-wire output to the controller input.
  • Define cable-lead termination for the bulk M12 assembly.