40mm sensing limit, 100Hz response ceiling, M30 body and 10V ~ 30V supply range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 40MM PNP M30 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
Active status supports this M30 sensor in a new machine
That leaves a clear call: design in the Omron E2E-X40MB1TL30 2M if the machine needs inductive detection with a PNP-NO, 3-wire output and has room for an unshielded M30 threaded body. All listed lifecycle signals say Active, and EU RoHS compliance is stated without a revision. Active status does not promise a 40mm trip for every target or mounting position.
Start the bracket with the unshielded body in mind, not a shielded sensor's mounting clearances. Cable leads also put termination on the machine build. The nickel-plated brass body and IP67/IP69K ingress ratings support considering it near spray, but they do not establish chemical compatibility.
The 40mm reach and 100Hz response set different limits
40mm is the listed sensing-distance ceiling, not a guaranteed trip point for every metal target. Target geometry and mounting decide whether detection works. The 100Hz response-frequency ceiling bounds the listed sensing rate; it does not specify the timing of a passing target.
The 10V ~ 30V supply range sets the rail boundaries. The -25°C ~ 70°C operating-temperature range defines the stated temperature envelope. Neither range gives the PNP output load-current limit.
Cable leads make the M30 station a wiring decision
Cable termination is the constraint at the M30 station. This sensor has cable leads, not a mating connector. Put that termination on the build instructions before releasing E2E-X40MB1TL30 2M; a connectorized station will need rework even if its input accepts PNP-NO. Don't let the matching thread size hide the harness change.
What still blocks the sensor bracket and input wiring?
The gaps are specific. The listing has no wire assignment, installation drawing, target-dependent sensing curve or PNP output load-current limit. Get those items from the datasheet before fixing the bracket or input wiring.
View the Win-Source product page for E2E-X40MB1TL30 2M.
Key Takeaways for Engineers & Buyers
- Check the 40mm sensing limit against the actual target and mounting position.
- Keep the machine rail within 10V ~ 30V.
- Specify cable-lead termination for the M30 mounting station.