40mm sensing ceiling, 100Hz response limit, unshielded M30 body and PNP-NO cable leads.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 40MM PNP M30 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
The unshielded M30 body is the design-in catch
Surrounding metal can affect detection at the unshielded M30 cylinder. Even with that mounting constraint, Omron E2E-X40MB1TL30 5M is Active across the listed lifecycle signals and is a candidate for new designs rather than a sustaining-only choice. EU RoHS compliance is listed. Plan the cable-lead route and termination with the sensor position; this is not a connectorized device.
The 40mm sensing distance is not a guaranteed trip gap
40mm is the sensing-distance ceiling, not a guaranteed trip gap for every target. The 100Hz response-frequency rating caps target-event rate but does not specify switching delay. Faster transitions need timing evidence beyond these ratings.
PNP-NO wiring decides whether this sensor fits the input
The input must match. PNP-NO, 3-Wire requires a compatible controller input; the wrong arrangement leaves the machine without the expected detection signal. The 10V ~ 30V supply range excludes a rail outside those bounds, while the -25°C ~ 70°C operating-temperature range sets ambient limits for placement. Neither range establishes the load the output can drive.
The bracket and output load still need hard answers
And the wiring question isn't the only one left open. The mounting drawing is absent, so metal clearance around the unshielded M30 cylinder remains unresolved; without that clearance, a bracket can make detection at the intended gap unreliable. Target-material correction curves are absent too. Test the actual workpiece rather than treating the 40mm ceiling as its trip gap.
The cable conductor assignment is not listed. PNP-NO, 3-Wire describes the interface but doesn't identify which lead connects where. No output load-current limit is listed to settle the controller-input load check, either. Get the mounting drawing and target-material correction curves before cutting the bracket; obtain the conductor assignment and output load-current limit before terminating the cable for E2E-X40MB1TL30 5M.
View the Win-Source product page for E2E-X40MB1TL30 5M.
Key Takeaways for Engineers & Buyers
- Test the actual workpiece against the 40mm sensing ceiling.
- Match the PNP-NO, 3-Wire output to the controller input.
- Leave mounting clearance around the unshielded M30 body.