Omron E2E-X40MB1TL30-M1: Active for New Machine Designs

E2E-X40MB1TL30-M1 Omron product image

40mm sensing distance, 10V ~ 30V supply and M30 threaded body; unshielded mounting needs room.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 40MM PNP M30 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V

Active status supports a new E2E-X40MB1TL30-M1 installation

Design it in. E2E-X40MB1TL30-M1 has aligned Active lifecycle signals, with no lifecycle reason here to confine it to sustaining designs. EU RoHS compliance is listed. The harder decision is physical: this unshielded inductive sensor has an M30 threaded body, so an electrical match alone won't settle whether it fits. Set the mounting and target geometry before committing to the installation.

The sensing gap and supply limits set the first boundaries

But that decision depends on the target working at the listed 40mm sensing distance. The figure alone does not establish the usable gap for a particular target or mounting arrangement. Supply is listed at 10V ~ 30V; 30V is the ceiling, not a preferred setpoint. Operating temperature runs from -25°C to 70°C, making 70°C the upper boundary to check at the sensor, including heat at its mounting point.

Can the running line mount and connect this M30 sensor?

Will the existing bracket and harness work? Start with clearance around the M30 threaded cylinder: its unshielded construction means a bracket can hold the body yet leave too little surrounding space for the sensing arrangement. Then check the input against the PNP-NO, 3-wire output. A mechanical fit won't keep the line running if that electrical interface is wrong.

Connector termination needs its own decision. Specify the mating connector before releasing the harness; “connector” does not fully define the interface. IP67 and IP69K ingress protection are listed for installations facing water exposure, but neither rating establishes whether the machine's mounting and connection preserve that protection. The box package does not change the installation work.

What the 100Hz figure cannot tell you

100Hz is the listed response frequency, not a switching-delay specification. Target-dependent sensing data, an output-load current limit, connector pinout and a mechanical drawing are also absent. Those gaps prevent release of E2E-X40MB1TL30-M1 on these figures alone.

View the Win-Source product page for E2E-X40MB1TL30-M1.

Key Takeaways for Engineers & Buyers

  • Check target geometry against the listed 40mm sensing distance before setting the stop.
  • Keep the supply within 10V ~ 30V; treat 30V as the ceiling.
  • Specify the mating connector for the PNP-NO, 3-wire harness before release.