40mm sensing distance, unshielded M30 body, 10V ~ 30V supply and PNP-NC cable leads.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 40MM PNP M30 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
The unshielded M30 mount is the first commitment
The 40mm reach and unshielded M30 body set the bracket constraint before wiring begins. E2E-X40MB2L30 5M suits new design-in when that mount and a PNP-NC input are intentional choices; it isn't a drop-in choice for a shielded mounting position. The lifecycle signals agree on Active. EU RoHS compliance is listed.
The supply range does not settle the load circuit
And the electrical side has its own limit: the listed 10V ~ 30V supply range puts 30V at the ceiling, not at a target operating point. Allow for transients at that ceiling. The range bounds rail selection but doesn't specify PNP-NC output load current. The -25°C ~ 70°C operating range states the ambient boundaries, not behavior beyond them. The 100Hz response-frequency figure is a sensing-rate ceiling, not a switching-time specification.
Can the target and controller use the listed 40mm reach?
40mm is the listed sensing distance. That figure gives the mechanical layout a starting point; it does not establish the distance available with the intended target material or mounting arrangement. The unshielded M30 threaded body needs a bracket that accommodates its sensing face. Treating it like a shielded sensor could leave the machine missing targets at the installed gap.
E2E-X40MB2L30 5M has a PNP-NC, 3-Wire output with cable leads, so the controller input and wiring scheme must suit that state and polarity. Get those wrong and a clear target can read as the wrong machine condition. IP67 and IP69K are listed ingress ratings that help with location choice where washdown is a concern, but neither settles the cable termination. On an existing line, preserve the same mounting and input assumptions when specifying this part.
Cable leads make the drawing the next purchase check
The mounting drawing is missing; Active status supports resolving that gap for a new build. Put E2E-X40MB2L30 5M on the BOM for a cable-lead assembly only after fixing the bracket and input wiring. The wiring diagram, target-material correction and output load-current limit are also absent here; each could change the assembly decision.
View the Win-Source product page for E2E-X40MB2L30 5M.
Key Takeaways for Engineers & Buyers
- Match the controller input to PNP-NC, 3-Wire before wiring the cable leads.
- Keep the supply within 10V ~ 30V; account for transients at the 30V ceiling.
- Reserve an unshielded M30 mount around the 40mm sensing path.