Omron E2E-X40MB2L30-R 2M: Active for new designs

E2E-X40MB2L30-R 2M Omron product image

40mm sensing, M30 threads, 10V ~ 30V supply, and -25°C ~ 70°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 40MM PNP M30 NC
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V

Unshielded mounting is the catch, not lifecycle

Unshielded mounting can demand space around the sensing face, a problem in a crowded machine frame. The lifecycle signal is clearer: all listed fields say Active, and E2E-X40MB2L30-R 2M is marked EU RoHS compliant. This industrial inductive sensor has an M30 threaded body and cable leads; choose it for a new design when the mount and PNP-NC, 3-Wire input are intentional. Wire the input for the opposite contact state and it will report the wrong machine condition.

The 40mm reach and 100Hz ceiling set different tests

The limits are workable. The listed 10V ~ 30V supply range bounds the rail choice; it does not authorize operation beyond either end. The 40mm sensing distance is a listed reach, not a guarantee across target materials or mounting arrangements, so test the trip point with the intended metal target and surrounding machine structure.

The 100Hz response-frequency rating is a ceiling on how quickly the sensor can follow events, not a switching-time specification for a moving target. The -25°C ~ 70°C operating-temperature range bounds the sensor environment. A cooler spot elsewhere in the enclosure doesn't establish the temperature at this mounting position.

Cable leads decide the production handoff

M30 threads establish the bracket interface, but cable leads decide the production handoff. Set the harness termination for E2E-X40MB2L30-R 2M before release to an existing production line. A Box package isn't a mating connector.

A fixed M30 bracket still needs the missing drawing

A fixed M30 bracket layout is wrong for this part until its mechanical drawing and unshielded mounting-clearance requirements are known. If the layout is still open, use those details to see whether the body can sit where the target path requires it. The cable wiring diagram and output load-current limit are also absent: one settles the PNP-NC connection, and the other determines whether the intended input load is permissible. Sensing distance answers neither question.

View the Win-Source product page for E2E-X40MB2L30-R 2M.

Key Takeaways for Engineers & Buyers

  • Check the 40mm target path against unshielded mounting clearance.
  • Keep the machine rail within the listed 10V ~ 30V supply range.
  • Define the cable-lead termination for the PNP-NC, 3-Wire input.