40mm sensing distance, M30 threaded body and 10V–30V supply bounds set the initial fit.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 40MM PNP M30 NO/NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
40mm reach makes mounting the first decision
40mm is the listed sensing distance, not a promise of detecting every metal target at that separation. E2E-X40MB3DL30-R 2M is a reasonable new design-in candidate: its lifecycle and product-status fields both say Active, with no conflict stated. The unshielded M30 threaded body belongs at a machine-mounted sensing point with room for the sensor and its surroundings, not at a position chosen from sensing distance alone. Its operating-temperature range is -25°C to 70°C; a location outside that range rules it out.
10V–30V supply bounds do not settle input timing
10V is the lower listed supply bound; 30V is the upper ceiling. Those bounds can rule out an incompatible control supply, but they do not establish output behavior at either extreme. The listed 100Hz response frequency is a ceiling, not a guaranteed rate of clean detections in every installation. A machine that needs faster events resolved needs a different frequency class. The stated PNP-NC/NO, 3-wire output must also match the controller input; sensing distance cannot rescue an electrical mismatch.
Will the PNP output match the line's input?
Can this replace the sensor on a running line? Active status doesn't answer that. The description calls out both normally closed and normally open operation, while the specification identifies a PNP, 3-wire output. Those details narrow the controller choice but do not show how either function is connected. For existing production, match the approved input circuit and cable termination to the ordered part rather than treating a shared M30 body style as proof of interchangeability.
IP67 and IP69K are listed ingress-protection ratings. They matter to the installation check where washdown or exposure drives the enclosure choice, but they do not settle whether the cable exit and mounting arrangement fit the machine. The specified nickel-plated brass body cannot answer that mechanical question either. EU RoHS compliance is stated.
M30 threads and cable leads constrain the build order
The M30 body and cable leads constrain the build order. Box describes packaging, not a different housing. Order E2E-X40MB3DL30-R 2M exactly, then match the received cable-lead unit to the approved assembly before it reaches the line.
The drawing and wiring details still matter
The gaps are specific. No pinout or dimensional drawing is listed, leaving the PNP connections and M30 installation space unresolved. An output-current limit is also absent, so the controller input and any connected load cannot be checked against a stated output ceiling. Without a target-dependent sensing curve, the 40mm distance is insufficient to set the final mounting position.
View the Win-Source product page for E2E-X40MB3DL30-R 2M.
Key Takeaways for Engineers & Buyers
- Check the 40mm sensing distance against the actual target and mounting position.
- Keep the supply within the listed 10V–30V bounds.
- Compare the 100Hz response-frequency ceiling with the required event rate.