Omron E2E-X40MC1L30 2M: Active for new designs

E2E-X40MC1L30 2M Omron product image

40mm sensing distance, 10V–30V supply limits, unshielded M30 body, NPN-NO output.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 40MM NPN M30 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V

The 40mm distance makes mounting the first decision

40mm is the listed sensing distance, not a guaranteed trip point in the installed fixture. The unshielded M30 threaded body must fit the target approach and surrounding metal before that distance is useful; drawing the fixture around the number alone risks missed detections. E2E-X40MC1L30 2M is Active and remains a candidate for a new machine.

The 10V to 30V figures are supply limits, not a preferred operating voltage. The -25°C to 70°C operating-temperature bounds rule out locations beyond them. Wiring matters too. The NPN-NO, 3-wire output needs a controller input arranged for that signal, rather than one chosen simply because the sensor fits the hole.

A 100Hz response limit does not define each transition

And 100Hz is only the response-frequency ceiling: it doesn't specify switching delay or guarantee detection at a particular machine speed. IP67 and IP69K ingress ratings support exposed industrial mounting, but cable routing remains a separate decision.

Will the cable leads fit the harness plan?

Will the cable leads reach the intended controller connection without a harness change? Settle termination and routing before committing the machine wiring. This sensor is Box-packaged, and all listed lifecycle signals say Active, with no conflict pushing it into sustaining-only use. EU RoHS compliance is listed, but no revision is specified.

The M30 mount still needs a drawing

Mounting clearance remains unresolved despite the M30 thread and 40mm sensing distance. The datasheet drawing and pinout are absent here; the drawing is needed to set mounting clearances, and the pinout to connect the NPN-NO cable leads. Hysteresis and target-dependent sensing information are also absent, so the listed distance cannot establish where this fixture will actually switch.

View the Win-Source product page for E2E-X40MC1L30 2M.

Key Takeaways for Engineers & Buyers

  • Place the target against the listed 40mm sensing distance before fixing the M30 mount.
  • Match the NPN-NO, 3-wire output to the controller input.
  • Keep the supply within the listed 10V to 30V limits.