40mm sensing, M30 unshielded body, 10V ~ 30V supply and NPN-NC output.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 40MM NPN M30 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
An NPN-NC sensor, not a PNP input replacement
A PNP-switching machine input is the wrong destination for this NPN-NC, 3-wire sensor. E2E-X40MC2L30 5M fits an industrial proximity-sensing input designed for that output behavior, provided the fixture accepts its unshielded M30 threaded body. Don't assume it can sit flush in surrounding metal.
The part is Active, with no stated lifecycle conflict, and EU RoHS compliant. New design-in is reasonable when the sensing geometry, output and mounting arrangement fit.
The 40mm reach depends on the installation
40mm is the listed sensing distance, not a guarantee that every metal target switches at that separation. With the unshielded M30 body, metal around the sensing face makes fixture geometry part of the decision, and the 100Hz response frequency gives a basis for checking target-event rate without establishing switching behavior for a particular target. IP67 and IP69K are listed ingress ratings; cable-lead entry into the machine still matters.
Can the line keep its cable-lead build?
Does the installed sensor use cable leads and an M30 threaded mount? If it does, retain E2E-X40MC2L30 5M by its complete part number on the BOM. The listed package is a box, not a connectorized version.
30V caps the supply; the wiring details remain open
30V is the listed supply ceiling; 10V is the lower boundary. The range can rule out an incompatible rail, but neither boundary is a preferred operating point or a statement of output load capability. The listed operating-temperature range is -25°C ~ 70°C; a location outside that span falls outside the stated operating range, not into an assumed margin. Neither range establishes what the sensor can switch at the input.
Before releasing the electrical connection, obtain the output load-current limit and conductor assignments from the datasheet. The mechanical drawing is needed to position the M30 body and cable exit, while sensing-distance test conditions are needed to judge the listed 40mm against the actual target.
View the Win-Source product page for E2E-X40MC2L30 5M.
Key Takeaways for Engineers & Buyers
- Match the M30 threaded body to the fixture before releasing the mount.
- Check the 100Hz response frequency against the fastest target event.
- Specify an NPN-NC, 3-wire input; get conductor assignments before wiring.